background image

© 2022 HyQuest Solutions

21

Obligations of the Operator and Disposal

EU WEEE Directive

As players in the environmental market, KISTERS AG and HyQuest Solutions are committed to supporting efforts to avoid
and recycle waste. Please consider: 

Avoidance before recycling!

Recycling before disposal!

This symbol 

 indicates that the scrapping of the unit must be carried out in accordance with Directive 2012/19/EU.

Please observe the local implementation of the directive and any accompanying or supplementary laws and regulations. 

Summary of Contents for iLevel-GW

Page 1: ...iLevel GW User Manual...

Page 2: ...8 Part III Configuration 9 3 1 Functions Settings 9 3 1 1 Setup 10 3 1 2 Service 10 3 1 3 Main Window 11 3 1 4 Parameters 12 3 1 5 Scale 13 3 1 6 More Buttons 13 3 2 GPRS GSM Setup 14 3 3 Two Point Ca...

Page 3: ...rmation provided in this manual was deemed accurate as of the publication date However updates to this information may have occurred This manual does not include all of the details of design productio...

Page 4: ...und before starting to work as well as for defects found while working Do not use the HyQuest Solutions iLevel GW in areas where there is a danger of explosion The present user manual specifies enviro...

Page 5: ...nd more specifically to determine groundwater and surface water levels Never use the the HyQuest Solutions iLevel GW to transport people Special caution is needed for all works and operations in the v...

Page 6: ...GW comes with a coupled water level and water temperature sensor accurate to 0 1 FS The vented pressure sensors auto compensate for atmospheric pressure and temperature variations providing a correcte...

Page 7: ...underfloor installations underfloor antennas are available Those are clamped between the frame and the lid Helical antennas are fitted onto the lid for above floor measuring points For fitting the ant...

Page 8: ...rting the battery incorrectly may blow the fuse which can only be repaired at the factory or even damage the electronics The electronic comes with a backup capacitor which can compensate a power outag...

Page 9: ...needed for the installation of the dongle are installed with the HyQuest Solutions GP shell Please use the supplied CD or download the latest version of the software from the customer homepage Double...

Page 10: ...your export file Optional Internet Upload Enabling this option data from third party loggers can be transmitted to the server Language Language for the user interface can be chosen from a drop down me...

Page 11: ...ronize Clock Synchronizes logger time with time of the current system Display Measure Show current measurement values status of logger and measured values of the activated measuring probe The values m...

Page 12: ...next modular time i e at a period of 1 h this would be the next full hour If for example a period of 12 hours is selected the measurements would be made at 0 00 and 12 00 With the Period Offset the ti...

Page 13: ...larms Check this option if you want to set special alarm events e g shorter measuring and transmissions intervals 3 1 5 Scale Offset Offset available if no pressure sensor is used for the water level...

Page 14: ...nding connection errors GSM period Set the transmission intervals in which the data is transmitted The minimum for this setting is five minutes Use the drop down menu to switch between seconds minutes...

Page 15: ...r will delete all logged data when 95 of the memory is used This will happen only if all data has been transmitted successfully GPRS Offset sec Time difference between the logger and the server in sec...

Page 16: ...ing the button Measure Set Point Nominal Enter the required current value This can be a currently measured tapping or the water level taking the main sea level into account Calculate and OK If all set...

Page 17: ...The software HyQuest Solutions GP Shell does not require any maintenance by the customer If an updated version is released 4 2 Loggers Our loggers only require very low maintenance Do not use any shar...

Page 18: ...your return shipment 2 Please provide as much information and or clear instructions within the return paperwork This will assist our test engineers with their diagnosis 3 Please do not ship the goods...

Page 19: ...finable minimum 2 Material and Environmental Conditions Enclosure stainless steel ABS Operating temperature range Modem 30 C to 85 C Logger 40 C to 85 C Dimensions Diameter Length Mass 48 5 mm 411 5 m...

Page 20: ...ctions must be observed 7 2 Dismantling Disposal When disposing of the units and their accessories the applicable local regulations regarding environment disposal and occupational safety must be obser...

Page 21: ...re committed to supporting efforts to avoid and recycle waste Please consider Avoidance before recycling Recycling before disposal This symbol indicates that the scrapping of the unit must be carried...

Page 22: ...ide the device rises rapidly within a very short time the hermetic sealing might be damaged This can happen due to material expansion caused by big temperature difference Please replace O rings and ca...

Page 23: ...S Group HyQuest Solutions KISTERS LATAM HyQuest Solutions NZ Ltd HyQuest Solutions Pty Ltd HyQuest Solutions KISTERS AG 49 2408 9385 0 info hyquestsolutions eu 612 9601 2022 sales hyquestsolutions com...

Page 24: ...www hyquestsolutions com 2022 HyQuest Solutions 21 04 2022...

Reviews: