MAINTENANCE AND PARTS
10-99
powermax
600
Operator Manual
5-7
Power Cord Replacement
Disconnect electrical power and gas supply before removing the old power cord.
Installation
1. Insert the new power cord through the strain relief.
2. Pass all 4 wires through the toroid, as shown (230 and 400 volt only).
3. Install the power cord connections where shown.
4. Tighten the strain relief onto the power cord.
5. Install the power supply cover.
6. Reconnect electrical power and gas supply.
208V - 240V
230V and 400V
PMX600.12
480V
230V
400V
YELLOW
GREEN
GREEN
BROWN
BLUE
BLACK
BLACK
WHITE
GREEN
BLACK
WHITE
RED
Pass all 4 wires through
the toroid 2 times.
Pass all 4 wires through
the toroid 3 times.
NOTE: Toroid must be installed for
power supply to be in compliance
with EMC standard EN50199.
WARNING
ELECTRIC SHOCK CAN KILL
Disconnect electrical power before performing any maintenance.
All work requiring removal of the power supply cover must be
performed by a qualified technician.