4 – Operation
Operate the plasma system
The following topics explain how to begin cutting with the plasma system.
Step 1 – Install the consumables
Before operating the plasma system
and hand torch, first make sure:
1.
The power switch on the power
supply is in the OFF (
O
) position.
2.
A complete set of consumables is
installed on the hand torch
as shown:
Electrode
Swirl ring
Nozzle
Retaining cap
Deflector*
*
Install the deflector by snapping it
securely into place on the retaining cap.
Do not apply grease or
other lubricants to the
O-rings on the electrode
and swirl ring.
These consumables are designed specifically for the Powermax30 AIR power supply and
Air T30 hand torch. They cannot be used with any other Powermax system or torch.
WARNING!
INSTANT-ON TORCHES
PLASMA ARC CAN CAUSE INJURY AND BURNS
The plasma arc ignites immediately when you pull the torch trigger. Make
sure the power is OFF (O) before changing consumables.
I
O
Tighten only to finger tight.
1
2
3
4
5
1
2
3
4
5
Summary of Contents for Powermax30 AIR
Page 6: ......
Page 24: ...24 Powermax30 AIR Service Manual 808850 1 Specifications ...
Page 32: ...32 Powermax30 AIR Service Manual 808850 2 Power Supply Setup ...
Page 96: ...96 Powermax30 AIR Service Manual 808850 5 Troubleshooting and System Tests ...
Page 184: ...184 Powermax30 AIR Service Manual 808850 6 Power Supply Component Replacement ...
Page 200: ...200 Powermax30 AIR Service Manual 808850 7 Torch Component Replacement ...
Page 223: ...Powermax30 AIR Service Manual 808850 223 9 Wiring Diagrams 013393 Rev A SHEET 2 of 2 ...