Powermax30 AIR
Service Manual
808850
175
6 – Power Supply Component Replacement
Replace the magnetics assembly
Replacement transformers and inductors (the magnetics) for this power supply are available only as a complete assembly
with the components already mounted on a metal base plate. You cannot replace individual components.
Remove the magnetics assembly
1.
Complete the following procedures:
a.
Set the power switch to OFF (
O
), and disconnect the power cord from the power source.
b.
c.
d.
e.
f.
g.
h.
Remove the internal compressor
2.
On the power board side of the power supply, remove the wires for the transformers and inductors. See
a.
Remove J13, J14, and J15, located on the front panel end of the power board.
b.
Remove J18 and J19, located on the rear panel end of the power board.
c.
Remove J20 and J21, located on the bottom center of the power board.
Figure 86
Kit number
Description
WORK LEAD (BLK)
AC
AC
R
w
TORCH
START
BLK
BLK
B
TORCH
START
Ferrite on CE power supplies only
J13
J14
J15
J21
J20
J19
J18
Summary of Contents for Powermax30 AIR
Page 6: ......
Page 24: ...24 Powermax30 AIR Service Manual 808850 1 Specifications ...
Page 32: ...32 Powermax30 AIR Service Manual 808850 2 Power Supply Setup ...
Page 96: ...96 Powermax30 AIR Service Manual 808850 5 Troubleshooting and System Tests ...
Page 184: ...184 Powermax30 AIR Service Manual 808850 6 Power Supply Component Replacement ...
Page 200: ...200 Powermax30 AIR Service Manual 808850 7 Torch Component Replacement ...
Page 223: ...Powermax30 AIR Service Manual 808850 223 9 Wiring Diagrams 013393 Rev A SHEET 2 of 2 ...