3-3
S
ETUP
Operator Manual
1
Power Cord plug (115V shown)
•
Cut cord close to plug.
2
230V plug
3
To load 1 (brass) terminal
4
To load 2 (brass) terminal
5
To ground (green) terminal
6
Outer shell
7
Cord grip
Strip cord insulation back in order to
separate conductors. Strip conductor
insulation back in order to make good
contact with plug terminals. Make
connections, reinstall outer shell and
cord grip and secure with screws.
Do not overtighten.
This procedure is required if the power supply is to be
connected to a 230V receptacle, or to a 115V receptacle
that requires a plug that is different from the plug on the
power cord.
This procedure is necessary if 230V input power is required.
See the procedure in Fig. 3-2 for installing a power cord plug.
2
1
3
2
4
5
6
7
1
Input Voltage Selector switch
2
Retaining screw
•
Remove screw and position
switch to select required
voltage.
•
Reinstall retaining screw
and tighten to secure switch
in place.
3
Power Cord plug (115V shown)
•
If plug does not match
voltage at receptacle or type
of receptacle, install suitable
plug as shown below.
4
115 or 230V receptacle (115V
shown)
•
To use rated output (see
specifications in section 2), an
individual branch circuit capable
of carrying 33A, 115V at 35%
duty cycle; or 18A, 230V at 35
duty cycle and protected by fuses
or circuit breakers is required.
Cut cord
here
1
4
3
Figure 3-1 Repositioning Input Voltage Selector Switch
Figure 3-2 Changing Power Cord Plugs