Powermax125
Service Manual 808070
233
9 – Power Supply Component Replacement
Install the quick disconnect receptacle
1.
Secure the quick disconnect receptacle to the front panel by tightening the 4 supplied mounting screws to 23 kg-cm
(20 inch-pounds). See
2.
From the front of the power supply, insert the small end of the silver-plated fitting into the center hole of the quick
disconnect receptacle until fully seated.
3.
Install the plastic washer over the silver-plated fitting and the plastic hub on the rear of the quick disconnect
receptacle.
4.
Place the ring terminal over the silver-plated fitting and tighten the brass nut onto the silver-plated fitting. Tighten the
nut to 46.1 kg-cm (40 inch-pounds), but do not overtighten – the plastic washer should be able to spin when the
brass nut is installed.
5.
Push the 90° push-to-connect fitting onto the silver-plated fitting until fully seated.
6.
Route the nozzle wires through the protective sheathing in the center panel.
7.
Route the torch interface cable through the center grommet.