8 – Troubleshooting and System Tests
If there is a fault and the diode bridge output value is correct:
Display the service screen (
) and confirm that the value “VL” is ±15% of AC line voltage.
Figure 21
If there is a fault and the “VL” value is correct:
Verify the DSP board by replacing it with a known good board.
If the DSP board is not the problem, replace the power board.