7.
Place the emergency stop assembly firmly against the front panel from the rear. Secure it with the large nut. Make
sure the yellow plate is oriented correctly. Screw on the emergency stop button by turning it clockwise. See
8.
Work the 120 V outlet out to the front of the panel from the rear. Secure the 120 V electrical box to the front panel
using 4 screws. Reinstall the 120 V outlet. See
Install the 120 V auxiliary outlet
9.
Place the 480 V electrical box and wires against the rear of the front panel. Run the wires through to the front, and
secure the electrical box using 4 screws. Reinstall the 480 V outlet. See
Install the 480 V auxiliary outlet
10.
Put the ground terminal in place on the front panel. Secure with the screw and washer. Make sure all metal-to-metal
contact areas are clean.
11.
Apply the labels. Refer to
for placement.
Figure 41
12.
Put the system’s top cover and side panels back in place. See
13.
Reconnect the negative (-) ground cable to the battery.
A
B
C
D1
E
F
G
H
I
D2
428506
428508
428507
Summary of Contents for Freedom 38 PPA
Page 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Page 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Page 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Page 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Page 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Page 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...