Freedom 38 PPA
Service Manual
809010
105
3 – System-Level Components
Replace the 120 V auxiliary outlet
Remove the 120 V auxiliary outlet
1.
Turn OFF the system. Make sure the power switch on the front panel is in the OFF (
O
) position.
2.
Wait for 30 seconds, then disconnect the battery’s negative (-) ground cable.
3.
Remove the 2 screws that secure the 120 V cover and gasket.
4.
Remove the 2 screws that secure the 120 V outlet. Pull the outlet out and loosen the terminal screws to disconnect
the wires from the outlet.
Install the 120 V auxiliary outlet
1.
On the new outlet connect the green wire
to the ground (green screw). Connect the white wire
to the silver
screw. Connect the black wire
to the brass screw.
Figure 36
2.
Insert the new outlet into the electrical box. Secure using 2 screws. Make sure the screws make contact with the
threaded holes of the electrical box, not the holes of the metal front panel.
3.
Put the cover and gasket back in place and secure with 2 screws.
4.
Reconnect the negative (-) ground cable to the battery.
5.
Test the GFCI circuit. See
Kit number
Description
Kit: 120 V (20 A) auxiliary outlet replacement
1
2
3
1
2
3
Summary of Contents for Freedom 38 PPA
Page 52: ...52 Freedom 38 PPA Service Manual 809010 1 Troubleshooting ...
Page 93: ...Freedom 38 PPA Service Manual 809010 93 3 System Level Components Figure 26 J6 J4 J3 J7 J5 ...
Page 214: ...214 Freedom 38 PPA Service Manual 809010 7 Parts ...
Page 216: ...216 Freedom 38 PPA Service Manual 809010 8 Wiring Diagrams ...
Page 217: ...217 AC wiring diagram AC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...
Page 218: ...218 12 VDC wiring diagram 12VDC WIRING DIAGRAM FREEDOM 38 PPA HYPERTHERM ...