56
Duramax/Duramax Hyamp Robotic Torches
Service Manual 807460
4 – Component Replacement
Replacing the positioning barrel
Remove the positioning barrel
1.
Turn OFF (
O
) the power, disconnect the gas supply, and disconnect the torch.
2.
Remove the consumables from the torch.
3.
Place the torch on a flat surface with the left half of the positioning barrel facing up.
The left half of the positioning barrel is the side with the screws.
It may be helpful to clamp the lead in place to keep it from moving.
4.
Remove the screws from the left half of the positioning barrel.
5.
Lift the left half of the positioning barrel away from the torch.
6.
The torch body fits snugly into the right half of the positioning barrel. While holding the torch body, gently press the
right half of the positioning barrel away from the torch body to remove it.
7.
Slide the cap-sensor switch off its mounting post.
Kit
Description
Kit: Duramax 180° robotic torch positioning barrel replacement
Kit: Duramax 90° robotic torch positioning barrel replacement
Kit: Duramax 45° robotic torch positioning barrel replacement
Kit: Duramax Hyamp 180° robotic torch barrel replacement