![Hypertherm Duramax Service Manual Download Page 31](http://html1.mh-extra.com/html/hypertherm/duramax/duramax_service-manual_2193761031.webp)
Duramax/Duramax Hyamp Robotic Torches
Service Manual 807460
31
2 – Torch Setup
For the recommended minimum bend radius of the torch lead, see
or
If you are using Hypertherm’s robotic torch clamp (228806), complete the following instructions:
1.
Mount the robotic torch clamp using one set of mounting holes (through hole or threaded).
Figure 11
2.
Separate the torch clamp by removing the 4 screws from the front half of the torch clamp.
A second positioning dowel is provided in the kit to be used for additional mounting
support, if necessary, or as a replacement part.
Figure 12
0.76 cm
(0.30 inch)
1.91 cm
(0.75 inch)
2
1
1
2
1
1
1
0.45 cm (0.18 inch) through hole
2
M4 x 0.7 threaded hole
1
2
3
4
5
1
Positioning dowel
2
Rear half of the clamp
3
Front half of the clamp
4
Screws (4)
5
Anti-rotational tabs
Summary of Contents for Duramax