5.1.5 IO alarm function (version 1.9.5 or above)
Steps: 1. Connect the host software to the sensor according to 5.1.1.
2. Click
Setting
to enter the alarm threshold setting interface.
3. The default value 99999 means that the axis is not monitored. After setting the alarm, click
Set
to make the settings take effect immediately.
4. If you need to save the alarm threshold settings, please
click the
Save user setting
button
on the
Advanced setting
menu, and then the relevant parameters will remain valid after
shutdown.
5.
Return to the “Plot” interface, and then you can see an
ALARM
button at the bottom.
When the button is green, it means that no IO alarm has been triggered. When the button
is red, it means that an IO alarm has been triggered. Click the button to reset the IO alarm.
Precautions:
1. The IO alarm is in overload alarm mode by default.
2. In the overload alarm mode, the alarm must be reset manually after it is triggered.
3. In the overload alarm mode, make sure that the sensor is not pressed when resetting
the alarm. Otherwise, the alarm will be triggered again.
4. In the overload alarm mode, the alarm threshold of the sensor is not affected by