background image

 

LITHIUM POLYMER/ION MODE

 (for 3.7V/cell types only!)

 

 
 

 

 

 

 

 

 

 

 

 

   

Number of LiPo Cells Wired in Series (Pack Voltage) 

1S 

3.7V 

2S 

7.4V 

3S 

11.1V 

4S 

14.8V 

5S 

18.5V 

6S 

22.2V 

 

 

 

 

 

 

 

             

 
                                                                                                                                                                   
 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

             

 

 

 

 

 

 

 

             

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

             

 
 
 

 

 
 
 

LiPo CHARGE 
C=3300mAh     6S

 

LiPo DISCHARGE 
D=1.00 A       6S 

 

LiPo CHARGE 
C=3300mAh      6S

 

LiPo CHARGE 
C=3300mAh      6S 

 

BATTERY CHECK 
WAIT PLEASE. . . .

 

 BALANCER CON. 
       CONNECTED

 

CHG   0:00   00000 
LP + 2.20A   22.200V

 

LiPo DISCHARGE 
D=1.00A        6S 

 

LiPo DISCHARGE 
D=1.00A        6S 

 

BATTERY CHECK 
WAIT PLEASE. . . .

 

BATTERY CHECK 
WAIT PLEASE. . . .

 

START 

INC

 

INC

 

INC

 

INC

 

DEC

DEC

DEC

 

DEC

 

INC

 

DEC

 

BATT TYPE 

START 

ENTER 

ENTER 

ENTER 

ENTER 

DCH   0:00   00000 
LP + 1.00A   22.200V

 

 
Setting LiPo battery capacity 
Adjust and set the correct battery capacity from 100mAh to 20000mAh with INC & DEC buttons 
(50mAh per step). Press the ENTER button to confirm setting. Charge rate is set on the basis of 
selected capacity, at 1C rate. Example: Li-Po cell of 1500mAh capacity: 1C = 1500mA (= 1.5A).     

LiPo CHARGE 
C=6000mAh      6S

 

LiPo CHARGE 

 
 
Setting Battery Voltage / Number of Cells in Series for LiPo battery packs 
Select the total battery voltage to be charged with ENTER, INC & DEC buttons. 

C=6000mAh      6S

 

LiPo DISCHARGE 

The charger knows the pack’s voltage both from the balancer connector and the cell count e.g. ‘6S’ 
 
NOTE: The EOS Series chargers have intelligent detection routines to help you avoid making 
mistakes, and LOW or HIGH VOLTAGE errors are displayed if battery voltage does not match your 
setting.  HOWEVER, under some circumstances, especially with over-discharged or damaged 
batteries, the safeguard could fail.  Therefore, be absolutely sure that you have correctly set pack 
voltage correctly before charging, every time!

 

Using the cell balancer for all Lithium packs is 

STRONGLY recommended, as it greatly increases safety. 
 
Setting discharge parameters 
Adjust to the desired discharge current from 0.10A to 1.00A (0.01A per step) with INC & DEC button. 
Press the ENTER button to confirm setting. Set pack voltage, 1S~6S as in charging example above.  
Autocut occurs automatically at 3.0V per cell. 

D=1.00 A        6S 

 

 

 

 

LiFe MODE [LiFePO4, A123] 
 

The LiFe charge/discharge modes are intended for cells with 3.3V nominal, with Lithium Phosphate chemistry.  The LiFe 
(LiFePO4 charge/discharge modes are intended for cells with 3.3V nominal produced by A123 Company, or other-brand 
LiFePO4 cells which are recognized to be of good quality from well-known makers. Choose LiFe for BATT TYPE, for charging 
such cells.  The LiFe charge mode MAY work with “no brand” LiFePO4 cells having 3.3V nominal voltage, but Hyperion has 
found  some  “knock  off”  cells  in  the  market  of  very  questionable  quality.    Customers who use A123 mode (LiFePO4 
mode) to charge such off-brand cells assume all risk. In no case does Hyperion HK Ltd. Accept liability due to the 
failure of the cell(s) during charging or discharging. 
 
Due to the nature of A123/LiFePO4 cells (wide divergence in cell voltages during charging) and due to the high rates at which 
some of these cells – such as A123 brand – can be charged, one MUST ALWAYS properly use the cell balancer function 
whenever charging in LiFe Mode; failure to do so will result in poor pack performance at best, and damage to cells at worst. 
Customers who charge in LiFe mode without balancer connected assume all risk of charger and battery failure! 
 

Summary of Contents for EOS0606iAD-B

Page 1: ...arger is ONLY for NiCd NiMH Lithium 3 7V cell A123 3 3V cell and Lead Acid 2 0V cell type cells DO NOT connect others such as 3 6V cell Lithium Ion or non rechargeable batteries Always place the charg...

Page 2: ...previously used battery configuration This is especially convenient if you often charge the same type of battery 1 If NiMh is not shown short push the BATT TYPE button to scroll through all battery t...

Page 3: ...ely sure that you have correctly set pack voltage correctly before charging every time Using the cell balancer for all Lithium packs is STRONGLY recommended as it greatly increases safety Setting disc...

Page 4: ...1 00 A 4S BATT TYPE LiFe CHARGE C 2300mAh 4S DEC INC INC ENTER ENTER LiFe CHARGE C 2300mAh 5S BATTERY CHECK WAIT PLEASE START CHG 0 00 00000 LF 2 50A 19 000V LiFe CHARGE C 4600mAh 5S LiFe CHARGE C 460...

Page 5: ...m values are NiCd 5mV cell NiMH 3mV cell In most cases these should be left alone Advanced users may wish to increase settings to archive a delayed charge termination but if set to high can result in...

Page 6: ...65 of capacity After a day of flying use STORE Mode to achieve this It is especially harmful to store lithium packs fully charged and should be avoided for more than a few days at most AVOID dischargi...

Page 7: ...l should reach the acceptable voltage lower limit for that cell type the charger will stop balancing the pack TROUBLESHOOTING 1 Check again that the battery you are trying to charge and the settings o...

Page 8: ...y and stop charging In some cases however the charger will begin charging at the lower voltage it sees as correct and watch all cells to confirm the incorrect setting For example if you connect a 3S p...

Reviews: