5-11 ELECTRICAL SYSTEM
● After confirming that the electrolyte has entered the battery
completely, remove the electrolyte containers from the battery.
Wait for around 20 minutes.
● Insert the caps into the filler holes, pressing in firmly so that the
top of the caps do not protrude above the upper surface of the
battery、s top cover.
● Using HYOSUNG pocket tester, measure the battery voltage. The tester
should indicate more than 12.5-12.6 V(DC)as shown in the Fig. If the
battery voltage is lower than the specification, charge the battery with
a battery charger.
SERVICING
Visually inspect the surface of the battery container. If any signs of
cracking or electrolyte leakage from the sides of the battery have
occurred, replace the battery with a new one. If the battery termi-
nals are found to be coated with rust or an acidic white powdery
substance, then this can be cleaned away with sandpaper.
CAUTION:
Never use anything except the specified battery.
Once install the caps to the battery, do not remove the
caps.
NOTE:
If no air bubbles are coming up from a filler port, tap the
bottom of the two or three times.
Never remove the container from the battery.
NOTE:
Initial charging for a new battery is recommended if
two years have elapsed since the date of manufac-
ture.