5-9 ELECTRICAL SYSTEM
Battary
PTC
Regurator/Rectifier
B/R
R
Y/W R/W
Magneto
�
�
Switch
�
�
Pocket tester : 09900-25002
OIL LEVEL CHECK LIGHT INSPECTION
Disconnect the L/W and B/W lead connector of the oil
level check light.
Connect a jumper wire between L/W and B/W wires
coming from the main wiring harness. With the ignition
switch turned ON, the oil level check light should flash.
If there is no flash, check the wiring harness continuity
and the bulb blown out.
OIL LEVEL SWITCH INSPECTION
Check the oil level switch for continuity between the lead
wire. If the tester does not show the value of 0 ~ 1
Ϊ
when the switch ring is in bottom position, file the contact
surface or replace the unit.
THERMOELEMENT