Chapter3. For the beginning operator Operator Manual
3-6
©
Hyosung TNS Inc.
All Rights Reserved.
<Note!>
You can only change the Shelved Mode combination while operating in Shelved Mode.
Once
a lock is “activated” in any mode, the Shelved Mode combination returns to the
Factory Default of 50-25-50
To change the Shelved Mode Combination:
1. Power Lock
EC
Turn the Dial to the left (CCW) until “EC” (Enter Combination) is displayed.
2. EC
Enter Shelved Mode Combination
OPr
Enter the current Shelved Mode combination (either 50-25-50 or a changed Shelved
Mode combination) by sequentially pressing those digits on the lock keypad. The
numbers will be displayed on the LCD as they are entered. When the combination
has been correctly entered, the LCD will read
OPr
, meaning "
OP
en
r
ight."
3. OPr
Retract Bolt
Turn the Dial to the right (CW) to retract the bolt
4. Open Door
5. Insert Change Key
Insert the change key into the change key socket on the back of the lock.
WARNING:
Do not close the door.
Leave the door open during this process until your are comfortable opening the lock
with the new combination.
6. Extend Bolt
Turn the Dial to the left (CCW) to extend the bolt.
7. Power Lock
Turn the dial to the left (CCW) until
(the Change Key symbol along with
Enter Combination) is displayed.
8.
Press #8
EcF
Press the “#” button followed by the “8” button. EcF (Enter current Factory
combination) will be displayed
9. EcF
Enter Current Shelved Mode Combination
EnF
Enter the current shelved mode combination, “EnF” (Enter new Factory combination)
will be displayed.
10. EnF
Enter New Combination
Cnf
Select and
enter the new combination. “CnF” (confirm new Factory combination)
will be displayed