Page 31
The deposits in the upper part of the cylinder
can be conductive and lead to unwanted cur-
rents between the electrode connections and
the sensor electrode and thus to the message
"cylinder full".
If electrical bridges have penetrated deep into
the material, the steam cylinder must be
replaced.
»
Check the base and its connections
for limescale deposits and clean if
necessary.
»
Insert new O-rings between the cyl-
inder halves, in the base and in the
steam hose adapter.
»
Put the cylinder halves together and
reconnect them with the flange
clamps.
»
When assembling the cylinder, make
sure that the brackets and reinforce-
ments are on top of each other.
Risk of functional disruption!
We generally advise against using limescale
removers or other cleaners. If these are nev-
ertheless used to clean the cylinder and the
electrodes, rinse the parts cleaned with them
thoroughly before putting the unit back into
operation. The cleaners may impair the con-
ductivity of the cylinder water.
9.3.3 Cleaning the connecting hoses,
base connections, fine filter
and drain pump
»
Check the connection hoses for con-
dition and free passage.
»
Check all connections of the cylinder
base for free passage.
»
Clean the hoses and connections if
necessary.
»
Remove the fine filter on the water
connection side from the solenoid
valve and clean it under running
water.
»
Clean the drain pump as described
in the section of the same name..
NOTICE
NOTICE