background image

Hygiena Cube

 ASY3206

Summary of Contents for ASY3206

Page 1: ...Hygiena Cube ASY3206...

Page 2: ...vice Specifications 8 7 Commissioning and Safety Insructions 9 8 Battery Insertion 10 9 Measurement Modes 11 10 Measurement Procedure 12 11 Reading Data from Memory 13 12 Remote Measurement 15 13 QC T...

Page 3: ...3 Contents Hygiena Cube USB Cable Strip Cassette Adaptor 3 Lithium Batteries Contents 1...

Page 4: ...ant and safety relevant information Manufacturer s instructions Consult instructions for use Date of manufacture year month Serial number Don t dispose in general trash For disposal of device please r...

Page 5: ...ectly can affect the measurement result The measurement data can be stored internally Every saved result includes a unique measurement ID test name lot number manufacturer and date and time The measur...

Page 6: ...ol measures in order to guarantee a high degree of quality Test specific analysis configurations are provided via RFID card for running the tests on the Hygiena Cube Results determined with the device...

Page 7: ...ests provided as a strips cassette a specific strip cassette adapter must be used A USB cable is included to download the data to a PC The reader contains a QC set consisting of QC cassette and RFID c...

Page 8: ...8 Device Specifications 6 Device Specifications Customized cassette adapter Battery compartment USB data cable connection Operating button Display...

Page 9: ...ntion The device shall not be opened Otherwise the warranty of the manufacturer is terminated Attention With proper usage there are no biological hazards coming from the device However when not handle...

Page 10: ...up see Fig into the tray one by one Then place the battery cover on and press slightly with a coin turning clockwise until it stops Natural oils found on hands should not come in contact with batteri...

Page 11: ...reviously uploaded via RFID card The result will be displayed and can be stored in the internal memory b Timer measurement This type of measurement follows a test specifically configured incubation pe...

Page 12: ...ult data may be displayed incorrectly Please contact your supplier for a replacement in this case 2 2 Self test After the display flash the reader runs a self test to check internal functions importan...

Page 13: ...er If you use a strip adapter you have to put the strip inside the adapter If you use a cassette adapter you have to put the adapter on top of the cassette Be sure that the adapter is correctly placed...

Page 14: ...ll show RFID or TEST depending on your reader configuration Each timer measurement can be stopped by pressing the button during the measurement 6 Test configuration data There are different possibilit...

Page 15: ...the reader proceeds to point 7 The configuration is still stored after turn off and can be used again after turn on until it is replaced with a new RFID transmission Attention The permanent version o...

Page 16: ...he saved results in chronological order There are different possibilities concerning result saving on the reader depending on the reader configuration If no saving is required or if data saving is dea...

Page 17: ...ess than 1 second to not store the result ON appears in the display proceed to point 4 if a new measurement will be started 12 Turn off If the device is switched on and will not be activated for about...

Page 18: ...ard on top of the reader and wait until the QC configuration data has been uploaded audible signal Alternatively select the QC test from the reader memory Briefly press the button again to start the Q...

Page 19: ...contact your supplier Display DATE The expiry date of the test seems to be exceeded Elimination The device checks the internally set time with the expiration date of the test Check the expiration date...

Page 20: ...ocedure Press the control button briefly 1 second the display will show ON and continue with 5 1 or 5 2 No function Despite pressing the button no information is visible on the screen Cause The batter...

Page 21: ...econd pressing of the button the displayed value can be changed When the wanted value is reached e g year press the button longer 1 second The appointed value will be stored and the next time informat...

Page 22: ...ta Transfer The device provides the possibility of data transfer to a PC or laptop for which a unique USB cable and the Cube DataReader Software are required The software can be downloaded from the we...

Page 23: ...onds Power supply 3 batteries CR2032 3 V 230 mAh or Cube specific power cord optional article also usable for data transfer to PC laptop Interface 4 pole 0 1 in 2 5 mm jack plug for power supply and U...

Page 24: ...glass on the bottom should be checked for impurities For cleaning a commercial cloth together with a commercial cleaning fluid e g for glass products is recommended The status of the batteries is mon...

Page 25: ...the Device As the device can be contaminated by any material it should be disinfected with appropriate safety equipment After removing the batteries dispose of the used device in accordance with the...

Page 26: ...dus trial Vallejo Delegaci n Gustavo A Madero C P 07700 CDMX M xico 52 55 5281 4108 y 5281 4146 International Hygiena International 8 Woodshots Meadow Watford Hertfordshire WD18 8YU UK 44 0 1923 81882...

Reviews: