background image

 

 

HYENA E-BIKE SYSTEMS 

 

Technical Data 

 

  Function 

Input voltage range 

100~240Vac 

 

Input frequency range 

47~63 Hz 

 

Rated output voltage 

42

±

0.2V 

 

Output current 

2±0.2A 

 

Minimum charger voltage 

20±2V 

 

 

  Characteristic 

Battery temperature identification 

Yes 

 

Battery over temperature protection 

Yes 

 

Operating Temperature 

0

~+40

℃ 

85%RH 

 

Storage Temperature 

-20

~+55

℃ 

95%RH 

 

Short circuit protection 

Yes 

 

Over current protection 

Yes 

 

Anti-adverse current protection 

Yes 

 

Internal temperature protection 

Yes 

 

Timing protection 

Yes 

 

 

  Parameter 

Dimension 

165*74*48mm 

 

Input Cable Connector (AC) 

Type B, F, G, I 

Refer to Pin Definition 

Input Cable Length 

1500±20mm 

 

Output Cable Connector (DC) 

BC-A320 

 

Output Cable Length 

1200±50mm 

 

 

  Certification 

CE 

EU 

 

GS/LVD 

EU 

 

EMC 

EU 

 

UL1310 

US 

 

FCC 

US 

 

RoHS 

EU/US 

 

*

  The  certification  of  charger  varies  from  different  countries.

 

 

Summary of Contents for Charger 2A

Page 1: ...his guideline is applicable for the Hyena e bike system only Version 210324 Copyright 2020 HYENA INC All Right Reserved This manual is intended primarily for the trained technician to install disassem...

Page 2: ...ions 1 Cable Pin Definition 2 Technical Data 3 Function 3 Characteristic 3 Parameter 3 Certification 3 Operation 4 Operation Instructions 4 Charging Instructions 4 Safety Instructions 6 Important Noti...

Page 3: ...of the adapter varies from different batteries please refer to page 2 Functional light instructions Status Indicator Stand by Green light stays on Be charging Red light stays on Fully charged Green li...

Page 4: ...HYENA E BIKE SYSTEMS 2 Cable Pin Definition DC Battery BC A320 PN 591007 US 591008 EU 591009 AU Type PIN NTC AC Area US EU UK AU Type Type B Type F Type G Type I Type PIN NTC...

Page 5: ...0 40 85 RH Storage Temperature 20 55 95 RH Short circuit protection Yes Over current protection Yes Anti adverse current protection Yes Internal temperature protection Yes Timing protection Yes Parame...

Page 6: ...her If they are used while damaged fire electric shocks or short circuits may occur Do not use the battery charger with commercially available electrical transformers designed for overseas use travel...

Page 7: ...y during the charging process CAUTION Do not place the battery charger at locations that are easily accessible to children Charge the Battery Pack Before and After Storage When you do not use the batt...

Page 8: ...nstalled and grounded in accordance with all local codes ordinances WARNING Improper connection of the equipment grounding conductor is able to result in a risk of electric shock Check with a qualifie...

Page 9: ...g so may result in fire or power leakage Disposal In accordance with Directive 2012 19 EU electronic devices that are no longer usable and defective drained batteries must be collected separately and...

Reviews: