Servicing

9

Servicing

9.1

Introduction

WARNING ! 

READ HEALTH AND SAFETY PRECAUTIONS 
BEFORE YOU START ANY SERVICE WORK.

SERVICING OF THE COMPRESSOR MUST ONLY 
BE CARRIED-OUT BY AUTHORISED PERSONS 
FULLY TRAINED AND COMPETENT IN THE 
MAINTENANCE, MAINS ELECTRICAL SUPPLY 
AND STARTER CONTROL EQUIPMENT OF 
HYDROVANE COMPRESSORS. THEY MUST 
FULLY UNDERSTAND AND ADOPT CORRECT 
AND SAFE WORKING PRACTICES.

If you are unable to carry-out the work safely in the required 
manner, your Hydrovane Distributor will be pleased to help.

Use genuine parts and approved oils during routine servicing, the 
following premium service kits are available:

Oil change kit, 2000 hour/12 months, use KO457EP, KO1122EP, 
or KO3045EP.

Maintenance kit, 4000 hour/2 year, use KM457EP, KM1122EP, or 
KM3045EP.

Full overhaul/top-up kit, 20000 hour/10 year, use KT457E, 
KT1122E or KT3045E.

9.2

Routine Service Schedule

The work listed in this section must be carried-out at the indicated 
running-hours, which must be regarded as a maximum. In dusty, 
hot or humid conditions, more frequent servicing may be 
necessary.

This section shows the minimum service requirements for your 
compressor. To ensure that the full maintenance programme is 
carried out, we recommend that your compressor is regularly 
serviced by an authorised Hydrovane Distributor.

9.3

Servicing (RS)

Servicing intervals and procedures are the same as specified for 
the standard fixed speed compressor of the same power (kW) 
rating.

The speed control unit does not require any routine servicing.

After very long periods, it is recommended that the speed control 
unit capacitors and cooling fan(s) be replaced to ensure continued 
reliability of the unit. Refer to your Hydrovane Distributor for 
details.

9.4

Check Compressor Operation

Assuming the compressor is serviced correctly, the machine is 
capable of operating in ambient temperatures up to a maximum of 
45°C (40°C RS). At this ambient temperature the oil  temperature 
will be typically 75°C to 85°C.

When the compressor is working, the temperature should be:-

Initial start-up and warm-up period. <70°C

Optimum working temperature.  75 - 85°C

High temperature.

90 -100°C

Warning ! Consult your Distributor. >107°C

9.4.1

Check Compressor Pressure 

It is necessary to unlock (key provided) and open the hinged front 
door panel and remove the top panel to view the pressure gauge.

Remove any fixing screws and pull the top panel from the snap fit 
location pegs or location slots and lift clear of the compressor.

The pressure gauge is located adjacent to the air filter.

9.4.2

Check oil level (Fig. 9.1)

With the compressor stopped check the oil level using the sight-
glass (A) fitted near the end of the oil filter. The sight glass should 
appear full, if only part full or empty top up with approved oil.

.

Fig. 9.1 - Oil Level Sight Glass Location

Summary of Contents for HB18

Page 1: ...User Handbook HV04 HV45 Models ACE Stationary Air Compressors ST 16135 00 Iss E 05 2009 GB...

Page 2: ......

Page 3: ...ion 9 4 2 Lifting and Handling Fig 4 1 and Fig 4 2 9 4 3 Model Weights 9 5 Installation and Commissioning 11 5 1 Positioning Your Compressor Basic Requirements 11 5 2 Ventilation Fig 5 1 11 5 3 Electr...

Page 4: ...Oil Filter Replacement Fig 9 3 24 9 10 Oil filling Top up Fig 9 3 25 9 11 Air Filter Replacement Fig 9 2 25 9 12 Oil Separator Replacement Fig 9 2 25 9 13 Clean Oil Cooler Aftercooler Fig 9 4 25 9 14...

Page 5: ...ir com 1 5 Model Range This Handbook relates to all ACE HV04 HV45 vertical range compressors and hypac models V04ACE07 4035D400 50Hz model V04ACE10 4035D400 50Hz model V04ACE07 4035S400 50Hz model V04...

Page 6: ...el V45ACE08 2036D150 60Hzmodel V45ACE10 2036D150 60Hzmodel V45ACE08 5736D150 60Hzmodel V45ACE10 5736D150 60Hz model The last three digits of the product code represent mark number changes you may rece...

Page 7: ...he compressor s vent down cycle is complete Release any pressure contained in the aftercooler or associated pipework Check that the compressor pressure gauge reads zero Do not proceed until it does Ca...

Page 8: ...e is any suspicion of aspiration into the lungs for example during vomiting admit to hospital immediately Pressure injection Obtain immediate medical attention even if injury appears minor Spillage So...

Page 9: ...e required Conditions or applications which prevent the compressor temperature stabilising between these parameters should be avoided Single speed HV30 HV45 and all RS units have automatic stop start...

Page 10: ...or 10 5 7 5 Servo Valve bar 8 0 or 11 0 8 0 Run on Time after PU secs RT 120 60 Run on Time to Stop secs ST 2 Pressure Display Units P 0 bar 1 psi 2 kpa Temperature Display Units T 0 C 1 F Vacuum Rel...

Page 11: ...8 0 Unload Pressure bar PU 8 5 or 10 5 8 5 Servo Valve bar 9 0 or 11 0 9 0 Run on Time after PU secs RT 60 8 bar 90 10bar 60 Run on Time to Stop secs ST 2 Pressure Display Units P 0 bar 1 psi 2 kpa Te...

Page 12: ...8 5 Servo Valve bar 9 0 or 11 0 9 0 Run on Time after PU secs RT 60 8 bar 90 10bar 60 Run on Time to Stop secs ST 2 Pressure Display Units P 0 bar 1 psi 2 kpa Temperature Display Units T 0 C 1 F Vacuu...

Page 13: ...the hypac or compressor and place it in the desired location Fig 4 2 ACED HV11 22 Hypac Compressor Damage to mountings may occur if you attempt to slide the compressor into position Take care when mo...

Page 14: ......

Page 15: ...ated in a moderate ambient temperature If temperatures frequently fall below 0 C consult your Hydrovane D istributor A different grade of oil may be required Compressor air intake and exhaust grills h...

Page 16: ...that the compressor is filled with approved oil and that all plugs are fitted securely Refer to Section 9 6 Access Panel Removal to remove the top panel so that the compressor pressure gauge can be v...

Page 17: ...vane standard single speed compressors feeding a common pressure system the minimum air line pressure of the RS compressor must be limited to the lowest maximum air line pressure of the single speed m...

Page 18: ......

Page 19: ...st savings due to the offload power reduction During offload run on time at minimum pressure the compressor will either stop with no air demand or return to onload running if more air is required Auto...

Page 20: ...the oil system is filtered by an oil filter L An oil level sight glass M is mounted adjacent to the oil filter The compressor is filled and topped up with oil via the oil filler N The sight glass M w...

Page 21: ...n and red LED indicators for three seconds Fig 7 1 The display then shows the software version code for a further three seconds before showing the normal operating display Single speed compressors all...

Page 22: ...s Mode Press the green START button the compressor will start and run continuously within the load unload PL PU pressure set points to match system demand On initial start with no pressure in the syst...

Page 23: ...r Remote start stop Filter differential pressure Normal operational mode Selected item locked as temporary default display Menu mode Page item locked adjustment inhibited Pressure set point indication...

Page 24: ......

Page 25: ...mperature Display Units h 01 15 Error Log A selected item will flash press plus up or minus down button to change a value or select an alternative press ENTER to select During changes if no key activi...

Page 26: ...adjustment or a lower pressure is required then carry out the following procedure a Turn the electrical supply on at the isolator disconnect the air outlet valve from the system and fit an air silence...

Page 27: ...Distributor 9 3 Servicing RS Servicing intervals and procedures are the same as specified for the standard fixed speed compressor of the same power kW rating The speed control unit does not require an...

Page 28: ...the top panel from the snap fit location pegs or location slots and lift clear of the compressor Check that the compressor pressure gauge reads zero 9 7 Oil Draining and Filter Replacement Fig 9 2 and...

Page 29: ...g area behind the cabinet filter B All discarded items and waste oil must be disposed of in an approved manner 9 14 Cabinet Air Filter Remove the disposable filter located in the rear panel by sliding...

Page 30: ...extreme ambients HPO oil should be used at the 2000 hour oil change periods If the oil is working above these temperatures the oil life will be significantly reduced If changing to Fluid Force Clear...

Page 31: ...X X X Check motor for damage X X X X Check motor starter for loose connections X X X X Check motor cables and earth X X X X Check motor for vibration X X X X Check flexible oil pipes X Check oil seal...

Page 32: ...otor for damage X X X Check motor starter for loose connections X X X Check motor cables and earth X X X Check motor for vibration X X X Check flexible oil pipes X Check oil seal for leakage X Check d...

Page 33: ...low General fault Emergency stop Excess pressure Power failure Above set temperature limit Lubrication oil oil level Dewpoint Motor Service due maintenance Filter differential filter service Er 0010 E...

Page 34: ...enu P21 For authorised engineers to install or service compressors as part of an approved installation or maintenance program 10 10 Diagnostic Menu P22 Allows an authorised technician to check and tes...

Page 35: ......

Page 36: ...ion of the Technical Publications Department Gardner Denver Ltd Gardner Denver Ltd Claybrook Drive Washford Industrial Estate Redditch Worcestershire B98 ODS United Kingdom Tel 44 0 1527 525522 Fax 44...

Reviews: