![Hydrotechnik HySense QL 326 Manual Download Page 38](http://html1.mh-extra.com/html/hydrotechnik/hysense-ql-326/hysense-ql-326_manual_2192491038.webp)
Programming values and times
Start and end values ramp A, start value ramp C:
ID
DLC
B0
B1
B2
B3
B4
B5
B6
B7
0x620
8
0x02
Start
ALSB
Start
AMSB
End
ALSB
End
AMSB
Start
CLSB
Start
CMSB
Duration Ramp A, Duration B, Ramp C:
ID
DLC
B0
B1
B2
B3
B4
B5
B6
B7
0x620
8
0x03
Duration
ALSB
Duration
AMSB
Duration
BLSB
Duration
BMSB
Duration
CLSB
Duration
CMSB
End value ramp C, values Duration times B and D:
ID
DLC
B0
B1
B2
B3
B4
B5
B6
B7
0x620
8
0x04
End
CLSB
End
CMSB
Value
BLSB
Value
BMSB
Value
DLSB
Value
DMSB
Duration time D:
ID
DLC
B0
B1
B2
B3
B4
B5
B6
B7
0x620
8
0x05
Duration
DLSB
Duration
DMSB
00
00
00
00
Save configuration
ID
DLC
B0
B1
B2
B3
B4
B5
B6
B7
0x620
8
80h
00h
00
00
00
00
00
00
The parameters are saved and remain until the next configuration.
End configuration
ID
DLC
B0
B1
B2
B3
B4
B5
B6
B7
0x620
8
99h
02h
00
00
00
00
00
00