0x55
0x01
Read status QL-TypeByte
[4] = Operating modeRx
: 40 55 01 00 02 33 32 36 ("326")
0x02
Read status firmware versionRx
: 40 55 02 00 31 2E 33 61 (firmware version 1.3a)
0x60
0x99
Save ConfigurationRx
: 60 99 00 00 00 00 00
0x79
uint8_tuint16_tuint8_t
uint32_t
SingleStep (e.g.: Tx: 79 03 01 00 00 00 00 00)
0x03Valve value
in 10mV steps0x000x00Rx
: 40 79 03 01 00 00 00 00
0x99
0x01
Parameter CONFIG ONRx
: 40 99 01 00 00 00 00
0x02
Parameter CONFIG OFFRx
: 40 99 02 00 00 00 00
0x03
Parameter CALIBRATION ONRx
: 40 99 03 00 00 00 00
0x04
Parameter CALIBRATION OFFRx
: 40 99 04 00 00 00 00
0xAA
0x01
Reset control box
Query of the control box
The control box reports with the Product-ID: 0x316AA000