ADDON SERIES - SYSTEM ASSEMBLY AND ACTIVATION PROCEDURES

 

 
 
PREPARATION – INSPECT ALL PARTS 

 

NOTE:  Read Mounting Bracket and System Plumbing  

Installation instructions on Page 1 and all  
instructions on this page 

 

before installing system. 

 

ADDON SERIES 

Addon Ultraviolet System  
Ultraviolet Lamp (in packing tube, 

#10

 or 

#20

 varies with model)

Mounting Screws (2 pieces) 
Warranty Card (please fill out and return) 
Installation Guide and Owners Manual 

 

NOTE:

  See Page 13 for Addon detailed parts breakdown.   

 

DISINFECT SYSTEM 

 

CAUTION:  QUARTZ SLEEVE IS VERY FRAGILE!   

For safety, wear a protective glove when 
handling quartz sleeve.  Do not touch quartz 
sleeve or UV lamp with bare hands.  Fingerprints 
will reduce effectiveness of the light. 

 

NOTE:  

Quartz sleeve is factory installed. 

 

NOTE:

  All Items refer to Figure 8. 

 
CAUTION: 

TIGHTEN COLLAR BY HAND ONLY.  Do not 
use tools as they will over-tighten and may 
damage sump.  Take care not to cut or pinch  
Addon Sump Gasket (Item 2). 

 
1.  Remove Collar (Item 15) from UV Head (Item 5). 
 

NOTE:

  Wipe all fingerprints and excessive lubricant from 

             quartz sleeve with isopropyl alcohol. 
 
2.  Disinfect the system (Pages 14-15, Steps 1-7). 
 

INSTALL ULTRAVIOLET LIGHT 

 

CAUTION:  DO NOT INSTALL A DAMAGED LAMP

 

 

NOTE:

  Hold UV lamp by ceramic ends only.   

             

Do not touch the glass.  Clean glass with  

             isopropyl alcohol if necessary. 
 
 
 
 
 
 
 

 
 
1.  Remove the UV Lamp (Item 16 or 16A) from packing tube 

and inspect it for damage.  If damage is found, contact the 
dealer for a replacement. 

 
2.  Connect UV lamp into the four-pin socket that is 

connected to the UV Control (Item 10). 

 
3.  Carefully insert the UV lamp through “O” Ring Retainer 

(Item 11) into the quartz sleeve as far as possible.  

 
       

NOTE:

  End of UV lamp will touch the bottom of  

                    quartz sleeve. 
 
4.  Slide Finish Cap (Item 12) on UV control cable and snap 

finish cap into “O” Ring Retainer (Item 11). 

 
 

ACTIVATE SYSTEM 

 

CAUTION:

  Verify that inlet and outlet ports are connected to 

                   

  

appropriate inlet/outlet pipes (see Figure 8). 

 

WARNING:

  NEVER LOOK DIRECTLY AT A LIGHTED UV 

                     LAMP.  ALWAYS LOOK AT LAMP THROUGH  
                     FINISH CAP ONLY. 
 
1.  Plug system into an electrical outlet.  The finish cap should 

illuminate within one minute, indicating UV lamp is on.  If it 
does not, unplug system, verify the UV lamp is securely  
plugged into four-pin socket, and repeat this Step. 

NOTE:

  UV lamp should remain on at all times during use     

             

  

because; repeated starting of UV lamp shortens 

            

      

lamp life, and UV lamp requires a warm up period  

             

 

of 1-2 minutes. 

 
2.  Turn on water supply and check for leaks. 
 
3.  Flush system, connectors, and water lines for several 

minutes to remove carbon fines.  

 

NOTE: 

When an ultraviolet water treatment system is unused 
for several hours, water within system could become 

  

warm.  This is a normal condition.  To cool the water, 
dispense water from system.   

 

NOTE: 

 System is now ready for use. 

 

 

Service Requirements 

Recommended Service Intervals 

To ensure the system operates at its optimum level, certain routine 

maintenance must be performed.  Frequency of maintenance performance 

will depend on source water quality and level of system usage. 

CLEAN:

  Every 3 to 6 months 

DISINFECT:  

At least once a year 

UV lamp #10 or #20: 

 Change Annually 

Quartz Sleeve #11 or #20: 

 Clean when changing lamp.  Replace only if 

damaged or cannot be cleaned by non-abrasive methods.  

 

Summary of Contents for UV A/O-1

Page 1: ...ECH COMPANY ULTRAVIOLET WATER TREATMENT SYSTEMS UVB SERIES UV20 SERIES UVBB SERIES RACK SYSTEM UV1 SERIES ADDON SERIES Hydrotech Inc 25555 West Avenue Stanford Valencia CA 91355 Phone 661 294 8888 Fax...

Page 2: ...RECOMMENDED INTERVALS 4 PARTS ILLUSTRATION 5 PARTS LIST 5 UVBB SERIES INSTALL QUARTZ SLEEVE AND DISINFECT SYSTEM 6 INSTALL ULTRAVIOLET LIGHT AND FILTERS 6 ACTIVATE SYSTEM 6 SERVICE REQUIREMENTS AND R...

Page 3: ...d and create active sites where pollutants can be collected by adsorption These new sites dramatically increase the total surface area and capacity of each granule WHAT IS ADSORPTION Adsorption is the...

Page 4: ...to avoid breaking the quartz sleeve UV Lamp Replacement Lamps must be changed every twelve months While UV lamps rarely burn out they do lose their disinfection power Use only PURA UV lamps as they ar...

Page 5: ...e and below UV system to service the sumps and UV lamp without removing the UV system The minimum space is UVB 11 above and below UV20 UVBB 20 above and below UV1 10 above and below ADDON 10 or 20 abo...

Page 6: ...sump wrench for removal only 4 Being careful not to dislodge quartz sleeve install sump with filter sleeve assembly onto UV head 5 For UVB2 UVB3 Models only Remove Sump Item 1 from Filter Head Item 2...

Page 7: ...801104 34202018 33004030 36005701 31910101 31910201 31910301 7 8 9 10 11 12 13 14 15 16 Switch Safety Indicator LED Fuse 1A Type 3AG Module UV Control 11 Screw 6 32 x 3 8 Screw 10 x 1 Screw 14 x 1 Was...

Page 8: ...ess steel channeling sleeve and sleeve gasket onto UV head 4 For UV20 2 UV20 3 Models only Remove Sump Item 1 from Filter Head Item 20 Install Filters Items 21 and 23 as shown in Figure 2 Install sump...

Page 9: ...01 7 8 9 10 11 12 13 14 15 Switch Safety Indicator LED Fuse 1A Type 3AG Module UV Control 20 Screw 6 32 x 3 8 Screw 10 x 1 Screw 14 x 1 Washer 14 Nylon O Ring Quartz Sleeve Standard 31000006 44302201...

Page 10: ...Y HAND ONLY Do not use tools as they will over tighten and may damage sump Take care not to cut or pinch O Rings Item 2 Use sump wrench for removal only 1 For UVBB 2 and UVBB 3 Models only Remove Sump...

Page 11: ...1 34202022 34202024 36005502 31910102 6A 6B 7 8 9 10 11 12 13 14 Mounting Bracket 2 Sump BB Mounting Bracket 3 Sump BB Switch Safety Indicator LED Fuse 1A Type 3AG Module UV Control BB Screw 6 32 x 3...

Page 12: ...he bottom of each Leg Item 2 NOTE Snug but do not tighten the bolts and nuts connecting the legs and top to the Corner Braces Item 4 until assembly has been squared 2 Attach two corner braces to the u...

Page 13: ...Configurations DATE INSTALLED SYSTEM OUTPUT RATING LPM GPM CONFIGURATION SERIES SERIES TO PARALLEL PARALLEL PARALLEL TO SERIES MODULE 1 TYPE PURA PART NUMBER MODULE 2 TYPE PURA PART NUMBER MODULE 3 TY...

Page 14: ...16 from packing tube and inspect it for damage If damage is found contact the dealer for a replacement 7 Connect UV lamp into the four pin socket that is connected to the UV Control Item 10 8 Careful...

Page 15: ...Filter Carbon EPCB 10 Gasket Filter Head UV 10 SL Mounting Bracket UV1 33801105 34201027 33004030 36005702 31910106 7 8 9 10 11 Retainer UV Lamp UV1 Washer 10 Nylon Screw 10 x 1 UV Control with Finis...

Page 16: ...o the UV Control Item 10 3 Carefully insert the UV lamp through O Ring Retainer Item 11 into the quartz sleeve as far as possible NOTE End of UV lamp will touch the bottom of quartz sleeve 4 Slide Fin...

Page 17: ...g Head UV Addon White 1gpm Head UV Addon White 3gpm 33803301 33803303 21001004 44301003 34202026 44301002 44301005 6 7 8 9 10 11 Mounting Bracket Addon Screw 10 x 1 Screw 8 x O Ring Quartz Sleeve Stan...

Page 18: ...wash with cleaning solution Rinse them well with clean potable water Inspect O rings for damage i e nicks or scratches Replace damaged O rings CAUTION Use care when cleaning UV head Do not get the UV...

Page 19: ...ON Use care when sanitizing UV head Do not get the UV control module or connectors wet 3 Remove sump from UV head and set aside CAUTION Do not touch quartz sleeve or UV lamp with bare hands Fingerprin...

Page 20: ...TY As a manufacturer we do not know the characteristics of your water supply The quality of water supplies may vary seasonally or over a period of time Your water usage may vary as well Water characte...

Reviews: