Before entering the spa or hot tub, the user should measure the water temperature with an
accurate thermometer.
The use of alcohol, drugs, or medication before or during spa or hot tub use may lead to
unconsciousness with the possibility of drowning.
Persons suffering from obesity or with a medical history of heart disease, low or high blood
pressure, circulatory system problems, or diabetes should consult a physician before
using a spa or hot tub.
Persons using medication should consult a physician before using a spa or hot tub since
some medication may affect heart rate, blood pressure, and circulation.
For Units with a GFCI (Ground Fault Circuit Interrupter)
This appliance is provided with a ground-fault-circuit-interrupter located on the control box.
Before each use and with the unit operating, push the test button. The unit should
stop operating and the reset button should appear. Push the reset button. The unit
should now operate normally. If the interrupter does not perform in this manner, a
ground current is flowing indicating the possibility of electrical shock. Disconnect the
power, or unplug from receptacle, until the fault has been identified and corrected.
For Cord and Plug Connected Units
Connect to a grounded, grounding type receptacle only. NEVER connect the spa to an
extension cord.
Do not bury the cord.
WARNING To reduce the risk of electrical shock, replace damaged cord immediately.
For Permanently Installed Units
A terminal marked “G” or “ground” is provided in the wiring box located inside the
equipment compartment. To reduce the risk of electric shock, connect the terminal
or connector to the grounding terminal of your electrical service or supply panel with
a continuous green insulated copper wire in accordance with National Electric Code
Table 250-95 and any other local codes in effect at the time of installation.
For Permanently Installed Units not Provided with an Internal
Disconnecting Method
The electrical supply for this product must include a suitably rated switch or circuit breaker
to open all ungrounded supply conductors to comply with Section 422-30 of the
National Electric Code, ANSI/NFPA 70 1978. The disconnecting means must be
readily accessible to the tub occupant but installed at least 5 feet (1.5m) from the tub
water.
For Units with Gas Heaters
WARNING - Do not install indoors. This unit uses a gas heater that requires proper
ventilation and is intended for outdoor use only.
For UL Listed Equipment Assemblies
Install at least 5 feet (1.5m) from tub water using nonmetallic plumbing. Install blower
no less than 1 foot (305mm) above the maximum water level to prevent water
from contacting electrical equipment. Install in accordance with blower installation
instructions.
To reduce the risk of drowning from hair and body entrapment, install a suction fitting(s) &
cover(s) with a marked flow rate in gallons-per-minute that equals or exceeds the flow
rate marked on the equipment assembly.