PRODUCT FEATURES 

 
 

1. 

GROUND FAULT CIRCUIT INTERRUPTER

 – This device is required for portable tubs as specified in the 

national electrical code article 680.  The GFCI is designed to protect against potential electrical shock 
hazard should a ground fault occur. 

 
2. 

THERMOSTAT

 - The thermostat regulates the water temperature of your tub. 

 
3. 

TIMECLOCK (Optional):

  Provides timer control over heating and filtering cycles 

 

4. 

PUMP RECEPTACLE 

– Connect pump here. 

 
5. 

POWER AIR SWITCH

 – Turns the system on and off 

 

6. 

SAFETY LIGHT CIRCUIT

 – 120V hot output for 12V light circuit 

 

7. 

SANITIZER CIRCUIT

 – Provides a 120V output when pump is running for a water sanitizer 

 

8. 

HIGH LIMIT

 - A safety switch that will shut the heater off if the temperature within the heater reaches a 

non-adjustable limit.  Push to reset. 

 

9. 

SYSTEM INTERFACE MODULE RECEPTACLE

 – Provides Auto-Fill and Auto-Drain function.  Auto-Fill 

Control (PT# 48-0042-K)  

 
10. 

REMOTE CONTROL RECEPTACLE:

  Provide remote thermostat control over the system.   

 

11. 

HEATER ASSEMBLY

 - Thermostatically controlled and equipped with a high-limit safety shut off. 

 
12. 

ROCKER SWITCH:  

Determines operation of the time clock.

 

 

13. 

PLUMBING HEADER ASSEMBLY 

– Connects the pump to the heater  

 
14. 

PUMP ASSEMBLY 

– Pumps water to and from the baptistery 

 
15. 

BASE 

– ABS base for mounting equipment 

 

 
 

Figure 1.0 

 
 
 

 

 
 

85-0130  REV.10 

 

    5/11 

 

5

Summary of Contents for BES6000-HC Series

Page 1: ...ERATION INSTALLATION MANUAL BAPTISTRY HEATER AND CONTROL SYSTEM BES6000 HC BES6000T HC SERIES 5 5KW BES6005 HC BES6005T HC SERIES 11 0KW HYDROQUIP 510A N SHERIDAN ST CORONA CA 92880 85 0130 REV 10 05...

Page 2: ...18 WARRANTY 19 HYDROQUIP PART NUMBERS HQ PART NUMBER DESCRIPTION BES 6005 HC 11KW HEATER SYSTEM BES 6000 HC 5 5KW HEATER SYSTEM CONTROL BES 6005T HC 11KW HEATER SYSTEM W TIMER SYSTEMS BES 6000T HC 5...

Page 3: ...ut at least 5 feet 1 5m from the tub water The electrical supply for permanently connected equipment systems must also include a suitably rated ground fault circuit interrupter GFCI to comply with art...

Page 4: ...tub unattended Infants should not be permitted in water temperatures more than 100f H Prolonged immersion in water that is warmer than normal body temperature can result in a dangerous condition known...

Page 5: ...ccur immediately disconnect electrical power from the equipment system and discontinue use of the tub until a qualified technician has identified and corrected the problem 11 DANGER risk of electrical...

Page 6: ...NITIZER CIRCUIT Provides a 120V output when pump is running for a water sanitizer 8 HIGH LIMIT A safety switch that will shut the heater off if the temperature within the heater reaches a non adjustab...

Page 7: ...ny local electrical codes in effect at the time of installation All electrical connections must be made in accordance with the wiring information contained in this manual or on the back of the field w...

Page 8: ...to malfunction and may void the warranty 3 Reinstall the control box faceplate 120 VOLT INSTALLATION Permanently Connected Units 1 Remove the faceplate from the control box to allow access to the inpu...

Page 9: ...BES COMPONENT CONNECTIONS 85 0130 REV 10 5 11 8...

Page 10: ...FLOAT SWITCH LEVEL KIT PLUMBING DIAGRAM 85 0130 REV 10 5 11 9...

Page 11: ...PRESSURE SWITCH LEVEL KIT PLUMBING DIAGRAM 85 0130 REV 10 5 11 10...

Page 12: ...SYSTEM INTERFACE MODULE SEE NEXT PAGE FOR IMPORTANT TIPS 85 0130 REV 10 5 11 11...

Page 13: ...LVE TIPS MAY BE INSTALLED ANYWHERE VALVE ASSY CAN BE EFFECTED BY WEIGHT SUPPORT IF NECESSARY FILL ASSY CAN BE PLUMBED VERTICALLY OR HORIZONTALLY TO BYPASS FILL VALVE LOSSEN SMALL BLACK SCREW NEXT TO S...

Page 14: ...3 DEPTH CONTROL BOX The control box contains all the electrical components necessary to operate your tub it also contains the field wiring compartment The System Interface Module D C GROUND FAULT CIRC...

Page 15: ...erature of the water The thermostat is located on the front of the control box W the thermostat knob to the middle of the Comfort Zone This setting will cause the wat temperature to rise to approximat...

Page 16: ...GNOSTIC CENTER ato provide real time diagnostics of the R ON Illuminated whenever the heater is activated ON Illum SYSTEM FUSE Illuminated when the main system fuse is blown o Possible indication of p...

Page 17: ...e ready for heating o switch may require some adjustment Turn the thermostat knob clockwise until the heat engages and set for de 4 temperature The pump will continue to run as long as tub is full and...

Page 18: ...at steps 1 3 switch nipple and one set on the Fill Drain air switch nipple 2 Insure Remote Control is plugged into receptacle from option control and that both thermostats on 3 Apply power and if no l...

Page 19: ...y are not clogged with debris 5 Check the water level and make sure it is above the jets and at the proper level on the skimmer opening 6 Check the pump for trapped air With the pump running loosen th...

Page 20: ...y the original retail purchaser The warranty does not cover any commercial use of this product in any way Pump seals O Rings gaskets are not covered by the Hydroquip Inc warranty during the first 12 m...

Page 21: ...ER Name _________________________________________________________________ Address _______________________________________________________________ City __________________________________ State ________...

Page 22: ...85 0130 REV 10 5 11 21...

Reviews: