background image

TABLE OF CONTENTS

 

 

 

IMPORTANT 

SAFETY 

INSTRUCTIONS 

     2 

PRODUCT FEATURES  

 

 

 

 

 

 

INSTALLATION/OPERATING 

CONSIDERATIONS 

   6 

ELECTRICAL 

INSTALLATION 

      7 

COMPONENT 

CONNECTIONS 

      8 

FLOAT 

SWITCH 

PLUMBING 

DIAGRAM 

     9 

PRESSURE 

SWITCH 

PLUMBING 

DIAGRAM 

    10 

SYSTEM 

INTERFACE 

MODULE      11 

PLUMBING TIPS 

 

 

 

 

 

 

 

12 

EQUIPMENT 

DESCRIPTION 

      13 

START UP 

 

 

 

 

 

 

 

 

15 

OPERATION 

 

 

 

 

 

 

 

 

16 

PROBLEM SOLVING   

 

 

 

 

 

 

18 

WARRANTY 

 

 

 

 

 

 

 

 

19 

 

 

 

HYDROQUIP PART NUMBERS 

 

  HQ PART NUMBER 

DESCRIPTION 

BES-6005-HC 11KW 

HEATER 

SYSTEM 

BES-6000-HC 

5.5KW HEATER SYSTEM 

CONTROL  

BES-6005T-HC 

11KW HEATER SYSTEM W/TIMER 

SYSTEMS 

BES-6000T-HC 

5.5KW HEATER SYSTEM W/TIMER 

48-0140F-K WATER 

FILL/LEVEL KIT (FLOAT) 

48-0140P-K WATER 

FILL/LEVEL KIT (PSI SWITCH) 

48-0141-K 

DRAIN CONTROL KIT  

KITS 

34-0038D25-D 

REMOTE CONTROL KIT  

48-0141C-K 

WATER LEVEL ASSY. (FLOAT) 

48-0148-K WATER 

LEVEL ASSY. (PSI SWITCH) 

48-0143-K 

WATER FILL ASSY. 

ASSEMBLIES 

48-0042-K 

SYSTEM INTERFACE MODULE  

 

 

 

 

 

 

 

85-0130  REV.10 

 

    5/11 

 

1

Summary of Contents for BES6000-HC Series

Page 1: ...ERATION INSTALLATION MANUAL BAPTISTRY HEATER AND CONTROL SYSTEM BES6000 HC BES6000T HC SERIES 5 5KW BES6005 HC BES6005T HC SERIES 11 0KW HYDROQUIP 510A N SHERIDAN ST CORONA CA 92880 85 0130 REV 10 05...

Page 2: ...18 WARRANTY 19 HYDROQUIP PART NUMBERS HQ PART NUMBER DESCRIPTION BES 6005 HC 11KW HEATER SYSTEM BES 6000 HC 5 5KW HEATER SYSTEM CONTROL BES 6005T HC 11KW HEATER SYSTEM W TIMER SYSTEMS BES 6000T HC 5...

Page 3: ...ut at least 5 feet 1 5m from the tub water The electrical supply for permanently connected equipment systems must also include a suitably rated ground fault circuit interrupter GFCI to comply with art...

Page 4: ...tub unattended Infants should not be permitted in water temperatures more than 100f H Prolonged immersion in water that is warmer than normal body temperature can result in a dangerous condition known...

Page 5: ...ccur immediately disconnect electrical power from the equipment system and discontinue use of the tub until a qualified technician has identified and corrected the problem 11 DANGER risk of electrical...

Page 6: ...NITIZER CIRCUIT Provides a 120V output when pump is running for a water sanitizer 8 HIGH LIMIT A safety switch that will shut the heater off if the temperature within the heater reaches a non adjustab...

Page 7: ...ny local electrical codes in effect at the time of installation All electrical connections must be made in accordance with the wiring information contained in this manual or on the back of the field w...

Page 8: ...to malfunction and may void the warranty 3 Reinstall the control box faceplate 120 VOLT INSTALLATION Permanently Connected Units 1 Remove the faceplate from the control box to allow access to the inpu...

Page 9: ...BES COMPONENT CONNECTIONS 85 0130 REV 10 5 11 8...

Page 10: ...FLOAT SWITCH LEVEL KIT PLUMBING DIAGRAM 85 0130 REV 10 5 11 9...

Page 11: ...PRESSURE SWITCH LEVEL KIT PLUMBING DIAGRAM 85 0130 REV 10 5 11 10...

Page 12: ...SYSTEM INTERFACE MODULE SEE NEXT PAGE FOR IMPORTANT TIPS 85 0130 REV 10 5 11 11...

Page 13: ...LVE TIPS MAY BE INSTALLED ANYWHERE VALVE ASSY CAN BE EFFECTED BY WEIGHT SUPPORT IF NECESSARY FILL ASSY CAN BE PLUMBED VERTICALLY OR HORIZONTALLY TO BYPASS FILL VALVE LOSSEN SMALL BLACK SCREW NEXT TO S...

Page 14: ...3 DEPTH CONTROL BOX The control box contains all the electrical components necessary to operate your tub it also contains the field wiring compartment The System Interface Module D C GROUND FAULT CIRC...

Page 15: ...erature of the water The thermostat is located on the front of the control box W the thermostat knob to the middle of the Comfort Zone This setting will cause the wat temperature to rise to approximat...

Page 16: ...GNOSTIC CENTER ato provide real time diagnostics of the R ON Illuminated whenever the heater is activated ON Illum SYSTEM FUSE Illuminated when the main system fuse is blown o Possible indication of p...

Page 17: ...e ready for heating o switch may require some adjustment Turn the thermostat knob clockwise until the heat engages and set for de 4 temperature The pump will continue to run as long as tub is full and...

Page 18: ...at steps 1 3 switch nipple and one set on the Fill Drain air switch nipple 2 Insure Remote Control is plugged into receptacle from option control and that both thermostats on 3 Apply power and if no l...

Page 19: ...y are not clogged with debris 5 Check the water level and make sure it is above the jets and at the proper level on the skimmer opening 6 Check the pump for trapped air With the pump running loosen th...

Page 20: ...y the original retail purchaser The warranty does not cover any commercial use of this product in any way Pump seals O Rings gaskets are not covered by the Hydroquip Inc warranty during the first 12 m...

Page 21: ...ER Name _________________________________________________________________ Address _______________________________________________________________ City __________________________________ State ________...

Page 22: ...85 0130 REV 10 5 11 21...

Reviews: