IMPORTANT ELECTRICAL SAFETY INSTRUCTIONS
1.
READ AND FOLLOW ALL INSTRUCTIONS
2.
Electrical installa on must be completed by a qualified electrician in accordance with all Na onal, Regional and Local
Codes and Regula ons in effect at the me of installa on.
3.
Connect only to a dedicated circuit protected by a class ‘A’ two
-
pole ground fault circuit interrupter (GFCI)
4.
Use copper conductors only!
5.
The hot tub equipment and all electrical plugs, outlets and lights within 1.5m (5 ) of the unit must be G.F.C.I protected.
Consult your electrician or local electrical authority for further details.
6.
A green colored terminal or a terminal marked “G”, “GR”, “Ground”, or “Grounding” is located inside the supply terminal
box or compartment. To reduce the risk of electric shock, this terminal must be connected to the grounding means
provided in the electric supply service panel with a con nuous copper wire equivalent in size to the circuit conductors
supplying the equipment.
7.
At least two lugs marked
“BONDING LUGS”
are provided on the external surface or on the inside of the supply terminal
box or compartment. To reduce the risk of electric shock, connect the local common bonding grid in the area of the hot
tub to these terminals with an insulated or bare copper conductor not smaller than No.6 AWG (Canada/Europe) / No.8
AWG (USA).
8.
All field installed metal components such as rails, ladders, drains or other similar hardware within 3 m (10 ) of the hot
tub shall be bonded to the equipment grounding bus with copper conductors not smaller than No.6 AWG.
G.F.C.I./R.C.D. APPLICATION GUIDE FOR HYDROPOOL SERENITY SERIES
NORTH AMERICA
4300 / 4500 / 6600 Models
40A
5900 / 6800 / 6900 Models
50A
EUROPE
All models
20A
SAFETY COMES FIRST. WHEN INSTALLING & USING THIS ELECTRICAL EQUIPMENT, BASIC SAFETY
PRECAUTIONS MUST ALWAYS BE FOLLOWED!
IMPORTANT NOTE:
• This guide is for standard installa ons where the wire run is 15 m (50 .) or less. For longer wire runs, consult a qualified
electrician.
FIGURE 1: ELECTRICAL CONDUIT LOCATION
IMPORTANT NOTE: (FIGURE 1)
The following dimensions can be used to determine the proper loca on of submerged conduits in concrete slab installa ons.
The dimensions are made from the outside of the spa / hot tub frame with the access for panels removed. The topside control
panel is shown at the bo om of the diagram as a reference.