Hydropath HydroFLOW i Series Manual Download Page 9

If you are unsure of any details of fitting or installation, please contact your local Hydropath 
representative for technical support.

•For protection against Limescale due to heating, the unit should be fitted on the 
cold feed to where the water is heated.

•For protection against limescale, the unit should be fitted after any pumps or filters 
as these can degrade the conditioning effect.

•To enhance flocculation, the ideal location is before the pump feeding a filter.

The unit operates by creating a potential
difference on the pipe on either side of the
ferrite

ring.

An

electrical

loop

is

created

whenever an electrical connection is made from
one side of the ferrite loop to the other, e.g. by
metal supports, wiring or pipework. A loop will
prevent the unit from operating correctly.

This problem can be solved by moving the unit
outside the electrical loop. If this is not possible,
the metal support brackets can be electrically
insulated. Installing the unit on a section of
plastic pipe eliminates the possibility of an
electrical loop.

The i Range unit can provide a range of benefits, including protection against 
limescale, treatment of biofouling and flocculation of particles. The most effective 
location for the unit depends on the result desired.

Brackets create loop

Wiring creates loop

Move unit out of loop

Electrically insulate 

brackets

Summary of Contents for HydroFLOW i Series

Page 1: ...HYDROPATH Technology The home of iRANGE ...

Page 2: ......

Page 3: ...aken by an authorised repair centre Panel Indicators The unit is fitted with LED indicator lights The Green LED indicates that the power is on and the Red indicates that a signal is being transmitted This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervis...

Page 4: ... at the time of installation The power supply must be isolated for example via an isolating switch or circuit breaker This is the sole responsibility of the user and the site safety officer must be consulted before installation is undertaken This equipment has no user serviceable parts Return to supplier for servicing If the equipment is used in a manner not specified by these instructions the pro...

Page 5: ...ware The HydroFLOW i Range water conditioner is specifically designed to combat limescale in commercial and or industrial applications by clustering mineral ions to enhance filtration by flocculating particles and to combat biofouling i Range units are most commonly used on heat exchangers and plumbing systems 45mm pipe 1 75 Arrow indicates shorter 109mm ferrite Arrow indicates longer 126mm ferrit...

Page 6: ...Place the bracket on the pipe If installing on a vertical pipe place the bracket with the smaller plate upwards to ease fitting of hexagon nuts Tighten steel hex nuts to secure clamps for smaller units Secure straps on larger units by tightening clamps with flathead screwdriver or hex socket driver WARNING The system must be used as specified Failure to do so will prevent correct operation of devi...

Page 7: ...rrite bar Insert this through the holding cage until the holes line up with the hexagon nuts Take a second ferrite insert a plastic thumb screw through both ferrite bars and loosely screw into hexagon nut Repeat on opposite side Plate Hexagon Nuts Ferrite bars Thumb screws WARNING The system must be used as specified Failure to do so will prevent correct operation of device and may impair safety D...

Page 8: ... are fragile In accordance with local code and regulations connect the junction box to the electrical power supply 87V 240V AC Energise the electrical power supply and ensure that the Red and Green LED lights on the unit are glowing brightly Thumb nut WARNING The system must be used as specified Failure to do so will prevent correct operation of device and may impair safety DO NOT POWER UP UNIT UN...

Page 9: ...lectrical loop is created whenever an electrical connection is made from one side of the ferrite loop to the other e g by metal supports wiring or pipework A loop will prevent the unit from operating correctly This problem can be solved by moving the unit outside the electrical loop If this is not possible the metal support brackets can be electrically insulated Installing the unit on a section of...

Page 10: ...5 3 1 2 4 2 1 0 2 4 4 i60 4 0 2 4 2 1 2 0 0 0 i100 1 5 2 6 4 1 2 0 0 0 i130 6 0 2 6 4 1 2 0 0 0 i150 3 5 2 8 6 1 2 0 0 0 i190 8 0 2 8 6 1 2 0 0 0 To register the product please visit hydropath com product registration Products must be registered to activate any warrantee or guarantee All goods are sold subject to our standard terms and conditions of sales copies of which are available upon request...

Page 11: ......

Page 12: ......

Reviews: