Hydro-Mix HT Mechanical Installation Guide HD0766 Rev 1.2.0 21
8.4
Mounting the Sensor
NEVER HIT THE CERAMIC DISC
THE CERAMIC IS VERY HARDWEARING BUT IS BRITTLE AND WILL
CRACK IF STRUCK
When installing the Hydro-Mix HT it is imperative that the Ceramic Face Plate is flush with the
internal wall. The sensor can be adjusted by up to 32mm by adjusting the position of the
Clamp Ring (Figure 18)
Maximum Insertion 32 mm
Figure 18: Minimum and Maximum Insertion
8.5
Installing the Sensor on to the Fixing Plate
8.5.1
Externally Mounted Fixing Plate
1. Once the Fixing Plate has been welded into position over the appropriately sized
hole, the distance from the external face of the Fixing Plate to the internal wall (x)
should be measured (Figure 19).
Wall/Floor
Fixing Plate
X
Figure 19: Measuring the Insertion Depth
2. Attach the Clamp Ring to the Hydro-Mix HT
3. Adjust the position of the Clamp Ring to match the required insertion depth (Figure
Summary of Contents for Hydro-Mix HT