Hydro-Mix HT Mechanical Installation Guide HD0766 Rev 1.2.0 17
8 Installing the Sensor
These instructions refer to installing the Hydro-Mix HT on a flat surface; all other
installation locations use the same mounting arrangement.
Each sensor is supplied with a Clamp Ring. When attached this allows the sensor to be
connected to the Fixing Plate which is welded externally or flush to the floor or wall of the
installation location.
The Clamp Ring facilitates the correct positioning and subsequent height adjustment of the
sensor.
Hydro-Mix HT
M8 Screw (x4)
Clamp Ring
Fixing Plate
Weld
Weld
Wall/Floor
Ø
92-95mm Hole for Sensor Clearance
Figure 10: Sensor Installation (Fixing Plate Externally mounted)
When installing the Fixing Plate flush with the internal wall (Figure 11) the supplied Spacer Plates
can be used to ensure the sensor is correctly aligned.
Ø
142mm Hole for Fixing Plate
Weld
Weld
Fixing Plate
Clamp Ring
Installation
Wall/Floor
Spacer Plates (x2)
Figure 11: Sensor Installation (Fixing Plate Flush mounted)
Summary of Contents for Hydro-Mix HT
Page 4: ...4 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Page 6: ...6 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Page 8: ...8 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Page 10: ...10 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...
Page 28: ...Chapter 3 Corrosion Protection 28 Hydro Mix HT Mechanical Installation Guide HD0766 Rev 1 2 0 ...