LIMITED WARRANTY

HYDROMATIC warrants to the original consumer purchaser (“Purchaser” or “You”) of HYDROMATIC Sump
Pumps, Effluent Pumps, Sewage Pumps (other than 2-1/2"), and Package Systems, that they will be free from
defects in material and workmanship for the Warranty Period of 36 months from date of manufacture.

Our warranty will not apply to any product that, in our sole judgement, has been subject to negligence,
misapplication, improper installation, or improper maintenance. Without limiting the foregoing, operating a
three phase motor with single phase power through a phase converter will void the warranty. Note also that 
three phase motors must be protected by three-leg, ambient compensated, extra-quick trip overload relays of
the recommended size or the warranty is void.

Your only remedy, and HYDROMATIC’s only duty, is that HYDROMATIC repair or replace defective products
(at HYDROMATIC’s choice). You must pay all labor and shipping charges associated with this warranty and
must request warranty service through the installing dealer as soon as a problem is discovered. No request
for service will be accepted if received after the Warranty Period has expired. This warranty is not transferable.

EXCEPTIONS: Hydromatic Special Application Pumps, Battery Back-Up Sump Pumps, Filtered Effluent
Pumps, Grinder Pumps, and 2-1/2" Sewage Pumps are warranted for a period of 12 months from date of
purchase or 18 months from date of manufacture, whichever comes first.

HYDROMATIC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT
DAMAGES WHATSOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND
IMPLIED WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES
SHALL NOT EXTEND BEYOND THE DURATION EXPRESSLY PROVIDED HEREIN.

Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on
the duration of an implied warranty, so the above limitations or exclusions may not apply to You. This warranty
gives You specific legal rights and You may also have other rights which vary from state to state.

This warranty supersedes and replaces all previous warranty publications.

HYDROMATIC

740 East 9th Street, Ashland, OH  44805

Phone: 888-957-8677  •  Fax: 888-840-7867  •  Web Site: http://www.hydromatic.com

Summary of Contents for SKV40

Page 1: ...ed outlet only When wiring to a system control connect the pump ground lead to the system ground 6 Be sure that construction and access to septic sumps conform with all OSHA requirements 7 Do not run the pump dry Dry running can overheat the pump causing burns to anyone handling it and will void the warranty 8 The pump normally runs hot To avoid burns when servicing pump allow it to cool for 20 mi...

Page 2: ...r protection is desired install a Q Alert audible alarm system in the sump pit For outdoor installations confer with your Hydromatic distributor Connect the power cord to a 3 prong grounded AC receptacle Hazardous voltage Can shock burn or kill DO NOT remove the grounding pin from the power cord Avoid using extension cords or 2 prong adapter plugs Insert the piggyback plug that comes from the wide...

Page 3: ... with new oil so that the surface of the oil is 1 4 above the motor windings Check Motor Windings 1 Use a quality volt ohm meter VOM when performing these inspections 2 Set the meter to Rx1 3 Touch both flat prongs of the power cord to the leads of the VOM and observe the readings a 230 Volt System 0 8 to 1 1 ohms b 115 Volt System 1 6 to 1 8 ohms Check Pump Ground 4 Set the meter to Rx100 5 Touch...

Page 4: ...nd tuck the wires up into the housing to prevent contact with the rotor 11 Assemble the motor housing to the seal plate with three capscrews 12 Check for seal leaks by pressurizing the pump to 7 to 9 PSI If air bubbles continue recheck seals 13 Fill the motor housing with high grade transformer oil 14 Adjust oil level to at least 1 4 6mm above the motor windings top plate or to the top of the stat...

Page 5: ... 6A Seal Half Stationary 1 05484 001 1 6B Seal Half Rotating 1 05484 003 1 7 Impeller 1 08498 003 1 8 Volute 1 21612D000 9 Diaphragm Switch 115V 10 1 51752 403 7 9 Diaphragm Switch 115V 20 1 51752 404 7 Wide Angle Float Switch 115V 10 1 13967 010 7 Wide Angle Float Switch 115V 20 1 13967 020 7 Wide Angle Float Switch 230V 20 1 13967 025 7 Vertical Switch 115V 10 1 14105 000 5 Vertical Switch 230V ...

Page 6: ...witch is caught up on something Inlet pipe is plugged Outlet pipe is plugged 7 Motor windings may be open Take unit to authorized service center B Pump runs but fails to 1 Be sure all valves in discharge pipe are fully open empty sump 2 Clean out discharge pipe and check valve 3 Check for blockage in pump inlet or impeller 4 Pump not sized properly A higher capacity pump may be required C Pump wil...

Page 7: ...quest for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Sewage Pumps are warranted for a period of 12 months from date of purchase or 18 months from date of manufacture whichever comes first HYDROMATIC SHALL NOT BE...

Page 8: ......

Reviews: