Hydromatic SKV40 Installation And Operation Manual And Parts Download Page 4

5.

Make sure that the shaft is clean.

6.

Hold the shaft with a screwdriver and start the impeller
on the shaft one or two turns.

7.

Add a drop of Loctite #277 to the threads and screw the
impeller on the rest of the way hand tight.

The impeller will force the ceramic seal into position.

NOTICE:

Excessive Loctite on the seal or bearing will cause

the shaft to seize.
8.

Remove the old square-cut O-ring and install the new 
O-ring. Avoid rolling the O-ring into position; lubricate and
stretch the new O-ring to fit.

9.

Install the seal plate on the volute with the three
capscrews.

10. Fasten the motor leads inside the motor housing and

tuck the wires up into the housing to prevent contact with
the rotor.

11. Assemble the motor housing to the seal plate with three

capscrews.

12. Check for seal leaks by pressurizing the pump to 7 to 9

PSI. If air bubbles continue, recheck seals.

13. Fill the motor housing with high-grade transformer oil.
14. Adjust oil level to at least 1/4" (6mm) above the motor

windings top plate or to the top of the stator.

NOTICE:

Do not fill the motor housing completely. Allow air

space for expansion.
15. Replace the oil fill plug.
16. Recheck winding resistance before applying power.
17. Plug the power cord into a grounded outlet and check the

pump operation. Motor should run smoothly and be free
of vibration.

4

Shaft Seal

Seal Plate

Impeller

V

ol

u

te

Motor Ho

u

sing

S

qu

are-C

u

t O-Ring

Oil Fill
Pl

u

g

Capscre

w

s

Capscre

w

s

Capscre

w

s

Pump Disassembly

Summary of Contents for SKV40

Page 1: ...ed outlet only When wiring to a system control connect the pump ground lead to the system ground 6 Be sure that construction and access to septic sumps conform with all OSHA requirements 7 Do not run the pump dry Dry running can overheat the pump causing burns to anyone handling it and will void the warranty 8 The pump normally runs hot To avoid burns when servicing pump allow it to cool for 20 mi...

Page 2: ...r protection is desired install a Q Alert audible alarm system in the sump pit For outdoor installations confer with your Hydromatic distributor Connect the power cord to a 3 prong grounded AC receptacle Hazardous voltage Can shock burn or kill DO NOT remove the grounding pin from the power cord Avoid using extension cords or 2 prong adapter plugs Insert the piggyback plug that comes from the wide...

Page 3: ... with new oil so that the surface of the oil is 1 4 above the motor windings Check Motor Windings 1 Use a quality volt ohm meter VOM when performing these inspections 2 Set the meter to Rx1 3 Touch both flat prongs of the power cord to the leads of the VOM and observe the readings a 230 Volt System 0 8 to 1 1 ohms b 115 Volt System 1 6 to 1 8 ohms Check Pump Ground 4 Set the meter to Rx100 5 Touch...

Page 4: ...nd tuck the wires up into the housing to prevent contact with the rotor 11 Assemble the motor housing to the seal plate with three capscrews 12 Check for seal leaks by pressurizing the pump to 7 to 9 PSI If air bubbles continue recheck seals 13 Fill the motor housing with high grade transformer oil 14 Adjust oil level to at least 1 4 6mm above the motor windings top plate or to the top of the stat...

Page 5: ... 6A Seal Half Stationary 1 05484 001 1 6B Seal Half Rotating 1 05484 003 1 7 Impeller 1 08498 003 1 8 Volute 1 21612D000 9 Diaphragm Switch 115V 10 1 51752 403 7 9 Diaphragm Switch 115V 20 1 51752 404 7 Wide Angle Float Switch 115V 10 1 13967 010 7 Wide Angle Float Switch 115V 20 1 13967 020 7 Wide Angle Float Switch 230V 20 1 13967 025 7 Vertical Switch 115V 10 1 14105 000 5 Vertical Switch 230V ...

Page 6: ...witch is caught up on something Inlet pipe is plugged Outlet pipe is plugged 7 Motor windings may be open Take unit to authorized service center B Pump runs but fails to 1 Be sure all valves in discharge pipe are fully open empty sump 2 Clean out discharge pipe and check valve 3 Check for blockage in pump inlet or impeller 4 Pump not sized properly A higher capacity pump may be required C Pump wil...

Page 7: ...quest for service will be accepted if received after the Warranty Period has expired This warranty is not transferable EXCEPTIONS Hydromatic Special Application Pumps Battery Back Up Sump Pumps Filtered Effluent Pumps Grinder Pumps and 2 1 2 Sewage Pumps are warranted for a period of 12 months from date of purchase or 18 months from date of manufacture whichever comes first HYDROMATIC SHALL NOT BE...