background image

Power : 

Operating Voltage :  

12V DC Nominal 

Recommended Battery : 

12V DC Sealed Lead Acid   (18Ah) 

 

 

 

(This will provide approx 50 days continuous 

   operation.) 

Low Battery cut-out : 

10.0 V DC 

Battery recharge recovery :  12.0V DC 

Operation Range :   

Up to 30m (100ft) of water pressure head with a  

 

 

 

max of 300m (900ft) of river line 

Purge : 

Gas Line Solenoid Current :  0.6Amps for 1 sec 

Solenoid Current :   

0.6 Amps for 27 secs 

Electronics Quiescent : 

10 mA 

Average battery 

 consumption : 

 

14mA continuous (based on 7 x 3hr purges and 

 

 

 

a 1m water level rise per day) 

Solar : 

 

 

A small 5Watt solar panel is sufficient to keep 

   the 

battery 

fully 

charged. 

Purge Sequence :   

1 secs    - N2 gas valve 

 

 

 

25 secs  - solenoid valve 

 

 

 

Once every 3 hours (fixed) and when the water  

 

 

 

level increases by 100mm or a manually initi-

   ated 

purge 

Transducer Pressure  

Connection : 

 

6.35mm (1/4 inch) tube 

River Line Connection : 

9.52mm (3/8 inch) tube 

 

Max River-line Length : 

200m (600ft) using 3/8 in OD and 1/8 ID tubing  

 

Operating Temperature  

Range 

  -30

o

C to +70

o

C  

 

Enclosure Size : 

 

150mm x 200mm x 90mm (H x W x D) 

 

 

 

6 inches x 8 inches x 3.5 inches 

 

Weight :   

 

1.8 kg  (4 lbs) 

SPECIFICATIONS 

Page 2 

MODEL HS-35 

Typical Installation For HS-35 

Nitro, Water Level System 

Hut 

WL3100 

GCO 

N2  

Bottle 

River 

HS-35 

12VDC, 

18AH 

Time 

Water 

Level 

Purge cycles 

3 hrs 

3 hrs 

3 hrs 

3 hrs 

100mm 

rises 

100mm 

rises 

Only 3 hr purge 

when water is falling 

Purge every 100mm 
when water is rising 

© Copyright 2008, Hydrological Services preserves the right to change this bulletin at any time without notice 

Reviews: