18
Membrane Operating Limits:
Very Important
• MEMBRANE TYPE: Thin Film Composite
• MAXIMUM OPERATING TEMPERATURE: 113° F (45° C)
• MAXIMUM OPERATING PRESSURE: 100 psi
• MAXIMUM FEED FLOW RATE: 2 GPM
• MAXIMUM TDS: <1000 PPM
• MAXIMUM HARDNESS: <10 Grains Per Gallon (170 PPM)
• PH RANGE, CONTINUOUS
• OPERATION: 2–11
• MAXIMUM FEED WATER TURBIDITY: 1 NTU
• MAXIMUM FEED SILT DENSITY INDEX (SDI): 5 SDI
• CHLORINE TOLERANCE: 0 PPM
• CHLORAMINE TOLERANCE: 0 PPM
• MANGANESE TOLERANCE: 0 PPM
• IRON TOLERANCE: <1 PPM
• SILICA TOLERANCE: <10 PPM
NOTE:
Operating your membranes outside of the parameters voids the warranty. Use only with
microbiologically safe water. Do not use with water of any unknown origin or water quality.
When in doubt contact HydroLogic to order a water analysis kit.
Carbon Filter: HL 22021
Protect your roots! Many cities are switching to chloramines as their primary method of
disinfection. Chloramines are most commonly formed when ammonia is added to chlorine to treat
drinking water, making it harder to remove. While our Green Coconut Carbon filters work great
for chlorine, the smaller molecule size of chloramines requires additional filtration to ensure your
root-supporting microbes are happy and healthy.
COMPONENT SPECIFICATIONS, CONT.
• Specialty Carbon Filter for 100% Chloramines Removal
• Meets NSF/ANSI component certification standards
• Meets Prop 65 standards
• 1,500 Gallon Capacity
• 100% USA Made
Summary of Contents for stealthRO150
Page 1: ...USER MANUAL...