background image

Thank you for purchasing the 

PHMH601013/PHMH601014

. This Phantom Dual CMh System is a 

highly versatile lighting system that allows you to operate a single 315W CMh lamp or both 315W 

CMH lamps at the same time. The system can be used in a standard vertical configuration (see cover 

image) or the reflectors can be rotated 90 degrees upward (and then the system turned so the 

reflectors face down) to give a low-profile hanging configuration that is ideal for tight spaces. Two 

intermediate reflector angles can also be set, for a total of four different configurations.
 The reflectors feature multifaceted 95% reflective European hammertone aluminum, giving 

excellent light uniformity and diffusion.
The attached Phantom Dual CMh 315W ballast features low frequency, square-wave technology and 

is silent, reliable, and energy-efficient. It has two discrete channels and power switches, and a USB 

port for Autopilot PX Series Lighting Controller compatibility. Input voltage options are 120V, 208V, 

and 240V(120V power cord included with system).

For information on additional Phantom products please visit PhantomBallasts.com.

Supply power for the ballast is based on typical commercial or residential input. This ballast must be 

used only with double jacketed 315W ceramic metal halide lamps for safety and proper operation.

ALWAYS DISCONNECT THE BALLAST’S POWER CORD  

BEFORE MOVING UNIT OR CHANGING LAMPS

WARNINGS

•  Use this Phantom Dual CMh system indoors only. Position it in an area away from excessive 

heat or contact with liquids.

•  The ballast does not rely on the luminance enclosure for protection against accidental contact 

with live parts.

•  Disconnect the power supply before performing any maintenance, lamp changes, or other 

modifications. 

•  Opening the ballast will void the warranty.
•  Do not use lamps of any type other than the 315W (T12 38 mm PGZX18 base) with this ballast. 

Not for use with external ignitors.

•  Do not use Hydrofarm’s TM01240 240V timer with this system. The TM01240 timer is not 

designed for use with electronic ballasts, and using it may cause the ballast to fail.

•  The CMh ballast included with this system is designed to be used with Hydrofarm power cords 

ONLY. Using it with other power cords, or modifying the power cord, will void the warranty

OVERVIEW

DUAL 315W CMH 120/240V SYSTEM

 (3100K AND 4200K)

2

Summary of Contents for PHANTOM CMH

Page 1: ...PHMH601013andPHMH601014 USER MANUAL DUAL 315W CMH 120 240V SYSTEM 3100K AND 4200K INSTRUCTIONS EN FRAN AIS 8 INSTRUCCIONES EN ESPA OL 14...

Page 2: ...ditional Phantom products please visit PhantomBallasts com Supply power for the ballast is based on typical commercial or residential input This ballast must be used only with double jacketed 315W cer...

Page 3: ...ST WHAT S INTHE BOX A Dual 315W CMh System B CMh Lamp x2 depending on model PHMH601013 3100K PHMH601014 4200K C Power Cord D RJ12 to RJ12 Cable E RJ Splitter F USB to RJ12 Cable G Wire Hanger B C D E...

Page 4: ...xInput Power OutputPowerSettings Power Factor Ignitor Voltage OCV THD CF ta tc 315W x2 120 240V 110 265V 764W 382W x2 60 85 100 105 0 97 3 5 kV 250V 8 1 414 1 6 40 C 104 F 80 C 176 F PHBMH6010 BALLAST...

Page 5: ...he lamp and the power grid Generally a number below 10 is considered desirable in an electronic ballast application CF Crest Factor A measurement of how clean the ballast power output wave is A perfec...

Page 6: ...lamp life and performance DETERMINE REFLECTOR POSITION The Dual CMh System can be set in four different configurations Depending on the amount of space in your grow area the system can be configured t...

Page 7: ...es built into the side of the ballast and also use the integrated hanger hole on the reflector armature between the two reflectors fig 2 Using Hydrofarm item LULIFT or other reliable hanging method su...

Page 8: ...ons sur les produits Phantom visitez PhantomBallasts com L alimentation pour le ballast est bas e sur une entr e commerciale ou r sidentielle typique Ce ballast doit tre utilis seulement avec des ampo...

Page 9: ...U DE LA BO TE A Syst me double 315W CMh B Ampoule CMh x2 en fonction du mod le PHMH601013 3100K PHMH601014 4200K C Cordon d alimentation D C ble RJ12 RJ12 E Diviseur RJ F C ble USB RJ12 G C ble de sus...

Page 10: ...onction nement Courant d entr e maximum R glagesde lapuissance desortie Facteurde puissance Tension d amor age OCV DHT FC Ta tc 315W x2 120 240V 110 265V 764W 382W x2 60 85 100 105 0 97 3 5 kV 250V 8...

Page 11: ...itable sur une application de ballast lectronique FC Facteur de cr te valuation de la nettet de l onde de puissance fournie du ballast Une onde sinuso dale de sortie parfaitement nette devrait avoir u...

Page 12: ...t la performance de l ampoule D TERMINATION DE LA POSITION DU R FLECTEUR Le Double Syst me Cmh peut tre r gl sur quatre configurations diff rentes En fonction de la quantit d espace de votre zone de c...

Page 13: ...u ballast et utiliser le crochet trou int gr sur l armature du r flecteur entre les deux r flecteurs fig 2 l aide de l l ment LULIFT d Hydrofarm ou autre m thode de suspension fiable suspendre le syst...

Page 14: ...de cualquier tienda o residencia Por razones de seguridad y para garantizar un correcto funcionamiento el balasto solo se debe utilizar con l mparas de haluro met lico de cer mica de 315 vatios y dobl...

Page 15: ...A Sistema CMH doble de 315 vatios B Dos l mparas CMH dependiendo del modelo PHMH601013 3100 kelvin PHMH601014 4200 kelvin C Cable de alimentaci n D Cable RJ12 a RJ12 E Duplicador RJ D Cable USB a RJ1...

Page 16: ...m ximade entrada Ajustesdela potenciadesalida Factorde potencia Voltajedel encendedor OCV THD CF Ta tc 315W x2 120 240V 110 265V 764W 382W x2 60 85 100 105 0 97 3 5 kV 250V 8 1 414 1 6 40 C 104 F 80 C...

Page 17: ...en un balasto electr nico CF factor de cresta una media de lo limpia que es la onda de salida del balasto Un seno de salida perfectamente limpio tendr a un CF de 1 414 Dado que en los sistemas el ctri...

Page 18: ...ha inicial Esto prolongar la vida y el mejorar el rendimiento de la l mpara DETERMINAR LA POSICI N DEL REFLECTOR El sistema CMH doble puede adoptar cuatro configuraciones diferentes Dependiendo del es...

Page 19: ...duzca los extremos del colgador de alambre en los dos agujeros que hay en los laterales del balasto y utilice el colgador agujero integrado en el armaz n entre los dos reflectores figura 2 Suspenda el...

Page 20: ...dur e de la garantie implicite ou l exclusion des dommages fortuits ou cons cutifs les limites ou exclusions mentionn es ci dessus peuvent donc ne pas tre applicables votre cas Hydrofarm se r serve le...