1. POWER CORD

Plug into normal 120V outlet. Your controller is rated to oper-
ate up to 10 amps of equipment. (10 amps is recommended 
maximum load for the 15 amp rated controller.) Make sure the 
circuit is rated for 15 amps or more and does not have other 
high wattage equipment on the same circuit.

2. CONTROL OUTLETS

Both of these outlets will be activated by either a rise in tem-
perature or humidity above the settings on the dials. Usually 
exhaust,  intake,  and/or  circulation  fans  are  used  to  control 
these  environmental  factors  by  increasing  air  flow.  Air  con-
ditioners or dehumidifiers could also be used. Do not exceed 
recommended maximum of 10 amps.

3. CIRCULATION OUTLET

This outlet is ON whenever the control unit is plugged in. This 
outlet  would  be  used  for  oscillating  fans  (constant  air  circu-
lation),  ionizers,  air  cleaners  or  other  devices  that  would  be 
operated continuously.

4. INTERMITTENT EQUIPMENT OUTLET

This  outlet  is  where  your  CO2  system  should  be  plugged 
directly in if you want it to shut off upon activation by your 
temperature  or  humidity  rise. This  will  prevent  wasting  CO2 
while your exhaust fans are on.

When using a Hydrofarm CO2 system, plug the timer upside 
down into the intermittent equipment outlet and recalculate 
your flowmeter setting following these steps:

1.

  Calculate  the  cubic  feet  of  your  growing  area. 

    (Length x  Width x  Height  =  Cubic Feet) 

2.

  Multiply Cubic Feet x .0012 to equal the amount 

of CO

2

 per hour for flow meter setting.

3.

  Set the flowmeter.

This is a higher setting than the CO2 instructions calculate 
because  the  CO2  system  timer  allows  for  slow  CO2  build 
up.  With  the  Deluxe  Climate  Controller  in  use,  the  CO2 
enhancement will be constant unless stopped by tempera-
ture  or  humidity  rise. The  garden  will  need  to  be  replen-
ished rapidly for optimum growth, thus the higher setting.

CO2 TIMER SETTING

To stop CO2 flow during dark cycle, the CO2 timer should be 
reset to go on and off with the lights. Manual timers may peri-
odically need to be adjusted to compensate for the “off” time 
when your fans are on. Digital timers with a battery back-up 
will hold the correct time even though the power is shut off 
to the timer when the fans are on. A digital timer upgrade is 
available from your Hydrofarm dealer.

THERMOSTAT CALIBRATION

Place a thermometer next to the controller. Allow it to stabi-
lize for an hour. Turn the temperature control knob slowly to 
match  the  thermometer  setting.  Using  a  small  screwdriver, 
gently  turn  the  calibration  screw  (in  the  hole  below  the 
temperature control knob) until a click is heard. This screw 
is  typically  tight  from  the  factory,  so  use  caution  with  firm 
pressure  when  turning.  It  is  now  calibrated.  The  humidity 
controller is factory calibrated and won't need adjustment.

©2005 Hydrofarm Inc. 
rev. 4/05

OTHER FINE PRODUCTS FROM HYDROFARM

- Hydrofarm High Intensity Grow Lights
- Light Track™ Systems
- Hydrofarm CO

2

 

Systems

GUARANTEE

All our controls are guaranteed to the original owner for one year from the date 
of purchase. Save your receipt/invoice — a copy is required for all warranty work. 
Misuse,  abuse,  or  failure  to  follow  instructions  are  not  covered.  If  you  have  a 
problem, recheck your system to isolate the problem. If this doesn’t remedy the 
situation, call the place of purchase to get a Return Authorization for the faulty 
part. Send only that part. Unauthorized returns will not be accepted.