INSTRUCTIONS
9
AACH100HP SPECIFICATIONS
Model AACH100HP
Rated Voltage 110‒120V
Rated Frequency 60Hz
Working Current 10.2A
Power 1 HP
*BTU 10050 BTU/H
Refrigerant R410a
Refrigerant Weight 420‒450g
Rate of Flow 5000‒15000 L/h
1320‒3900 G/h
Reservoir Capacity 80‒250 gal (300-950 L)
Weight 69 lbs
Size 21.92
"
x 15.75
"
x 20.28
"
1. The rate of flow is decided according to the max jet of the pump (immersible pump or other
external power filter) and the circulation equipment.
2. The refrigeration performance test is indicated when the ambient temperature is 100°F (34°C),
the reservior capacity is 132 gal to 396 gal, the chilling effciency reaches its best.
3. The refrigeration efficiency is determined according to the installation location, heating source,
lighting, pump filter and other connecting parts.
4. When there is not enough circulation in a room, the refrigeration efficiency is reduced.
*The BTU is measured at an ambient temperature of 97°F (36°C) and the chiller is working
at 1100W/9.6A power.
Recommended pump: Hydrofarm AAPW1010 or AAPC1010 or AAPC1020 or AAPC20