BOOST FUNCTION
The boost feature accelerates the chilling process with two available options: 2-hour expedited
maximum chilling and continuous (24 hrs/day, 7 days/week) maximum chilling.
To engage the boost feaure, press BOOST once. The LED on the left marked “2 hours” will light. The
boost function is now set to accellerate chilling for 2 hours, after which boosted chilling will stop and
the chiller will return to the regular setting.
To set the boost function to constant operation, press BOOST twice. The LED under “24/7” will light.
The chiller will now continue in boosted mode until the BOOST pad is pressed again.
COMPRESSOR OPERATION:
The refrigeration compressor will automatically turn off when the water reaches, or is below, the set
temperature. When the compressor turns off, it will stay off for approximately 3 minutes or until the
water is 3 degrees above the set temperature.
An indicator light in the top right portion of the display will appear when the compressor is active. The
indicator light will disappear when the set water temperature has been reached, and will blink when
the compressor is in the 3 minute protection mode.
ERROR CODE:
Certain text will appear on the display panel in the event of an error. “P1” is an example that means
there is a defect in the temperature sensor. If error codes are appearing on the display, return the unit
to the original place of purchase for a warranty assessment.
CLEANING AND MAINTENANCE
Flushing of the internal chiller components is recommended at least once every 1-2 months to ensure
optimum performance and efficiency. Over time, nutrient deposits and other debris may accumulate
inside the chiller, reducing its effectivness.
Note: Do NOT use soap or detergents for cleaning the internal components of the chiller system.
1. Disconnect the chiller and submersible water pump from the power supply.
2. Clean off the pump with a high powered hose or sprayer to remove debris and dirt from the pre-
1. Temperature indicator
2. Temperature display
3. Point indicator
4. Key for decreasing temperature
5. Key for increasing temperature
6. Key for setting temperature
7. Working state indicator
Summary of Contents for ActiveAqua AACH100HP
Page 1: ...INSTRUCTIONS WATER CHILLERS AACH10HP AACH25HP AACH50HP AACH100HP ...
Page 2: ...INSTRUCTIONS www Hydrofarm com 2 AACH10HP CHILLER 1 10 HP 10 40 GALLON ...
Page 4: ...INSTRUCTIONS www Hydrofarm com 4 AACH25HP CHILLER 1 4 HP 26 80 GALLON ...
Page 6: ...INSTRUCTIONS www Hydrofarm com 6 AACH50HP CHILLER 1 2 HP 52 132 GALLON ...
Page 8: ...INSTRUCTIONS www Hydrofarm com 8 AACH100HP CHILLER 1 HP 80 250 GALLON ...