7
INSTRUCTIONS
AACH50 SPECIFICATIONS
Model AACH50
Rated Voltage 110-120V
Rated Frequency 60Hz
Working Current 4.4A
Power 1/2HP
*BTU 12010 BTU/H
Water Temperature Before Refrigeration 82°F (28°C)
Water Temperature After Refrigeration (Water Refrigerated 150L) 60°F
Refrigerant R134a
Refrigerant Weight 250 - 280g
Rate of Flow 1000 - 2500L/h
264-660G/h
Weight 48.5 lbs
Size 18.7” x 14.2” x 19.3”
1. The rate of flow is decided according to the max jet of the pump (immersible pump or other
external power filter) and the circulation equipment.
2. The refrigeration performance test is indicated when the ambient temperature is 88°F (30°C),
the water temperature before refrigeration is 86°F (28°C), the setting temperature is 61°F (16°C)
and the aquarium capacity is 52 GAL to 132 GAL. When reservoir capacity falls, the water
temperature will drop faster.
3. The refrigeration efficiency is determined according to the installation location, heating source,
lighting, pump filter and other connecting parts.
4. When there is not enough circulation in a room, the refrigeration efficiency is reduced.
* The BTU is measured at an ambient temperature of 97°F (36°C) and the Chiller is working
at 1100W/9.6A power.
Recommended Pump: Hydrofarm AAPW550 or AAPW800