COMPRESSOR OPERATION:

The refrigeration compressor will automatically turn off when the water reaches, or is below, the set 

temperature. When the compressor turns off, it will stay off for approximately 3 minutes or until the 

water is 1 degree above the set temperature.
An indicator light in the top right portion of the display will appear when the compressor is active. The 

indicator light will disappear when the set water temperature has been reached, and will blink when 

the compressor is in the 3 minute protection mode.

ERROR CODE:

Certain text will appear on the display panel in the event of an error. “P1” is an example that means 

there is a defect in the temperature sensor. If error codes are appearing on the display, return the unit 
to the original place of purchase for a warranty assessment.

CLEANING AND MAINTENANCE

Flushing of the internal chiller components is recommended at least once every 1-2 months to ensure 

optimum performance and efficiency. Over time, nutrient deposits and other debris may accumulate 

inside the chiller, reducing its effectivness.

Note: Do NOT use soap or detergents for cleaning the internal components of the chiller system.

1.  Disconnect the chiller and submersible water pump from the power supply. 
2.  Clean off the pump with a high powered hose or sprayer to remove debris and dirt from the pre-

filter and housing. Clean the pre-filter as well if one is used.

3.  Reconnect the pump to the chiller inflow tubing and place it in a clean reservoir.

4.  Fill the reservoir with clean water and a flushing agent formulated to remove salt deposits and 

excess nutrients from the plant system and grow medium (available at most indoor gardening and 

hydroponic retailers). Note: Using a flushing agent is completely optional.

5.  Plug in the pump and allow it to run for at least 1 hour so that the projected solution contacts all 

of the internal components used in the chiller during operation. Unplug the pump and empty the 

reservoir solution.

6.  Repeat steps 4 and 5 with clean water ONLY.

1. Temperature indicator
2. Temperature display
3. Point indicator

4. Key for decreasing temperature

5. Key for increasing temperature

6. Key for setting temperature
7. Working state indicator

Summary of Contents for ACTIVE AQUA AACH10

Page 1: ...INSTRUCTIONS WATER CHILLERS AACH10 AACH25 AACH50 AACH100 ...

Page 2: ...board Top cover Water inlet outlet adaptor AACH10 PERFORMANCE CURVE THE REFRIGERATION PERFORMANCE TEST IS INDICATED WHEN THE AMBIENT TEMPERATURE IS 86 F 30 C the water temperature before refrigeration is 82 F 28 C and the water refrigerated is 150 L 40 gal When water refrigeration is reduced the water temperature will drop down to any degree above 39 F 4 C in a short period of time AACH10 CHILLER ...

Page 3: ... decided according to the max jet of the pump immersible pump or other external power filter and the circulation equipment 2 The refrigeration performance test is indicated when the ambient temperature is 88 F 30 C the water temperature before refrigeration is 86 F 28 C the setting temperature is 54 F 12 C and the aquarium capacity is 13 gal to 50 gal When reservoir capacity falls the water temper...

Page 4: ...ront cover Front cover Control panel Front trim cover Circuit board Top cover AACH25 PERFORMANCE CURVE THE REFRIGERATION PERFORMANCE TEST IS INDICATED WHEN THE AMBIENT TEMPERATURE IS 86 F 30 C the water temperature before refrigeration is 82 F 28 C and the water refrigerated is 150L 40 gal When water refrigeration is reduced the water temperature will drop down to any degree above 39 F 4 C in a sh...

Page 5: ...ulation equipment 2 The refrigeration performance test is indicated when the ambient temperature is 88 F 30 C the water temperature before refrigeration is 86 F 28 C the setting temperature is 61 F 16 C and the aquarium capacity is 52 GAL to 132 GAL When reservoir capacity falls the water temperature will drop faster 3 The refrigeration efficiency is determined according to the installation locati...

Page 6: ...front cover Front cover Control panel Front trim cover Circuit board Top cover AACH50 PERFORMANCE CURVE THE REFRIGERATION PERFORMANCE TEST IS INDICATED WHEN THE AMBIENT TEMPERATURE IS 86 F 30 C the water temperature before refrigeration is 82 F 28 C and the water refrigerated is 150L 40 gal When water refrigeration is reduced the water temperature will drop down to any degree above 39 F 4 C in a s...

Page 7: ...rculation equipment 2 The refrigeration performance test is indicated when the ambient temperature is 88 F 30 C the water temperature before refrigeration is 86 F 28 C the setting temperature is 61 F 16 C and the aquarium capacity is 52 GAL to 132 GAL When reservoir capacity falls the water temperature will drop faster 3 The refrigeration efficiency is determined according to the installation loca...

Page 8: ...se Tank with evaporator Fan Back cover Filter front cover Front cover Control panel Front trim cover Circuit board Top cover AACH100 PERFORMANCE CURVE THE REFRIGERATION PERFORMANCE TEST IS INDICATED WHEN THE AMBIENT TEMPERATURE IS 88 F 31 C the water temperature before refrigeration is 86 F 30 C and the water refrigerated is 500L 132 GAL 1000L 264 gal and 2000 L 528 GAL ...

Page 9: ... decided according to the max jet of the pump immersible pump or other external power filter and the circulation equipment 2 The refrigeration performance test is indicated when the ambient temperature is 88 F 30 C the water temperature before refrigeration is 86 F 28 C the setting temperature is 61 F 16 C and the aquarium capacity is 79 GAL to 159 GAL When reservoir capacity falls the water tempe...

Page 10: ...uter control system The high quality condenser is manufactured by American OAK production line Anti corrosive pure titanium evaporator for fresh and salt water The compressor protection device system is built to shut off the circuit automatically to prevent the motor from burning out when the motor is overheating Temperature memory system that allows the chiller to refrigerate continuously accordi...

Page 11: ...vent personal injuries or damage to the chiller Please familiarize yourself with the symbols below before reading the manual or trying to operate the chiller TERMS AND SYMBOLS Hazard levels will be indicated in writing or shown by pictures The symbol on the left provides general emphasis of the hazard but specific details of the action which must be taken will be shown by a picture or explanation ...

Page 12: ...MBLY INSTRUCTIONS 1 Remove the chiller unit and all of the contained hardware from the box and packaging material 2 Set the chiller unit upright in the desired area on a stable surface ensuring there is at least 1 of clearance around the body sides top and back of the unit 3 Install the inlet outlet fittings onto the inflow and outflow threaded sites NOTE If the inflow and outflow fittings are dif...

Page 13: ...nlight high temperature exposure and high humidity Do NOT submerse the chiller Doing so will damage the unit and may inflict electric shock SETTING THE TEMPERATURE 1 Press and hold the SET button down for approximately 3 seconds to enter the water temperature programming mode The previous water temperature setting will display 2 Use the or buttons on the control panel to increase or decrease the d...

Page 14: ...deposits and other debris may accumulate inside the chiller reducing its effectivness Note Do NOT use soap or detergents for cleaning the internal components of the chiller system 1 Disconnect the chiller and submersible water pump from the power supply 2 Clean off the pump with a high powered hose or sprayer to remove debris and dirt from the pre filter and housing Clean the pre filter as well if...

Page 15: ... The unit doesn t run and the display is blank Power is not turned on Turn on the power Plugged in incorrectly Be sure the power cord is fully plugged in The unit cycles on and off Wrong voltage and or frequency Apply to correct power source Chiller is in protection mode A Check if the water circulation is normal B If the fan and the Chiller dissipate heat normally wait for 3 minutes and the unit ...

Page 16: ...ou autres en rapport avec le produit Certains états n autorisent aucune limite concernant la durée de la garantie implicite ou l exclusion des dommages fortuits ou consécutifs les limites ou exclusions mentionnées ci dessus peuvent donc ne pas être applicables à votre cas Hydrofarm se réserve le droit de réparer ou remplacer le Chiller couvert par cette garantie si celui ci est renvoyé au lieu d a...

Reviews: