background image

 4

www.hydrofarm.com

DRAINAGE INSTALLATION

 Install the included drain pipe to the draining 

nozzle on the machine and direct the pipe to 

the desired area before operate the machine. 
 If in need to replace or extend the drainage 

pipe, use ID Ø16mm, or 5/8in, piping.

 

WARNING:

 Do not block the drainage hose. 

The end of the drainage pipe should not be 

higher than the outlet hole. If the drainage 

pipe end is higher than the outlet hole, water 

will not drain properly and could damage 

components of the unit. 

MACHINE SETUP AND 

OPERATION

KEY FUNCTIONS

POWER

 – Turns the unit on and off.

CONTINUOUS OPERATION

 – When pressed, 

the unit will operate continuously. 

TIMER/MODE

 – The unit has 5 modes: 

Humidity, Current Time, Timed Operation On, 

Timed Operation Off, and Exit. Every time you 

press the Timer/Mode key it cycles to the next 

mode. 

“+” KEY

 – When in the “

SET

” mode, every time 

you press the “

+

” key, it will raise the humidity 

by 1%. If you hold the key down, it will add 

humidity more quickly. When in any of the time 

modes, the “

+

” key adds hours. These keys are 

used to set “

CURRENT

” time, “

TIMING ON

”, 

and “

TIMING OFF

.”

“–“ KEY

 – When in the “

SET

” mode, every time 

you press the “

” key, it will lower the humidity 

by 1%. If you hold the key down, it will lower 

humidity more quickly. When in any of the 

time modes, the “

” key adds minutes. These 

keys are used to set “

CURRENT

” time, “

TIMING 

ON

”, and “

TIMING OFF

.”

HUMIDITY AND TIMER SETUP

When the machine is powered on for the 

first time there will be an audible buzz sound. 

Please note that the machine has a default 

setting for humidity.

1. 

Press the 

POWER

 button to start the 

machine. The screen will display “

Run

” and 

Current

,” the present humidity.

Run

INSTRUCTION MANUAL

Drainage 

Nozzle

Drainage Pipe

Summary of Contents for AADHC180P

Page 1: ...INSTRUCTION MANUAL DEHUMIDIFIER AADHC180P ...

Page 2: ...ment or repair FEATURES Large capacity Moveable and easy to store Built in auto defrost system to protect key working components Adjustable humidity Timed operation Quiet running Energy saving design SPECIFICATIONS Model AADHC180P Rated capacity 180Pints Day Power supply 120V 60Hz Rated input current 11 3A Rated input power 1350W Max condenser pressure 3 6MPa Max evaporator pressure 1 2MPa Freon t...

Page 3: ...3 m INSTRUCTION MANUAL PRODUCT DRAWINGS FRONT BACK Control Panel Air In Louver Front Panel Drainage Pipe Power Cord Side Handle Compressor Heat Vent Back Handle Air Out Louver Side Handle FRONT BACK ...

Page 4: ...and Exit Every time you press the Timer Mode key it cycles to the next mode KEY When in the SET mode every time you press the key it will raise the humidity by 1 If you hold the key down it will add humidity more quickly When in any of the time modes the key adds hours These keys are used to set CURRENT time TIMING ON and TIMING OFF KEY When in the SET mode every time you press the key it will low...

Page 5: ...ime but not the real current time You are highly recommended to set the current time 4 To set for timed operation press TIMER MODE a third time and Timing on will display Use the button to change hour and the button to change minutes The timer is in 24 hour format Run Set 5 After you press TIMER MODE a fourth time Timing off will display Use the button to change hour and the button to change minut...

Page 6: ...S OPERATION button to enter the continuous operation mode The screen will show Continuous Run 2 Press the CONTINUOUS OPERATION button again to deactivate continuous operation The machine goes back to the mode of operating according to the humidity set point When there is a frost buildup the machine will be forced to stop dehumidifying and start defrosting automatically The screen shows the machine...

Page 7: ...he unit for an extended period of time please store it per the following steps 1 Clean the filter mesh ATTENTION The evaporator inside the machine has to be dried out before the unit is packed to avoid component damage and molds Unplug the unit and place it in a dry open area for a few days to dry it out TIP Another way to dry the unit is to set the humidity point higher than the ambient humidity ...

Page 8: ...esiredhumiditylevelhasbeenreached Reduceddehumidifier capacity Filtermeshisjammed Cleanthefiltermeshaccordingtomanual Air inand orAir outlouversare jammed CleartheblockagefromAir inand orAir outlouvers Noairinlet FiltermeshorAir inlouveris jammed Cleanfilteraccordingtoinstructionsorcleanthelouver blockage LoudOperation Machineissituatedonaninclineor declineslope Movetoalevellocation Filtermeshisja...

Reviews: