14
Based on Energy
Content of 1,000
BTU/Cubic
ft:
Divide
each
appliance's BTU/h
requirement
by
Take into account
the distance the
10' (3.1 m) Length
10' (3.1 m)
Length
1,000 B
TU/ft
3
to get
5' (1.5 m) Length
3/4" Pipe size
15' (4.6 m) Length
1/2" Pipe size
the appliance's
ft
3
/h
1-1/4" Pipe size
A
B
1" Pipe size
requirement.
gas chart to properly
Gas meter
size the line.
5' (1.5 m) Length
10' (3.1 m) Length
15' (4.6 m) Length
appliance is from
1-1/4" Pipe size
3/4" Pipe size
C
1/2" Pipe size
the gas meter, then
look in the above
Boiler
199,000 BTU/h
Dryer
35,000 BTU/h
Furnace
120,000 BTU/h
Range
65,000 BTU/h
For
sections
of the
gas line supplying gas to more than one appliance
(Ex:
Point A to Point B), add up the cubic
ft.
per hour requirements
of the appliances that are being supplied by that
section,
and size to the farthest appliance.
For Ex
ample:
The
section
from A to B supplies gas to the furnace, range and dryer. Adding up the BTU/h requirements
and dividing by 1,000 yields a cubic
ft.
per hour requirement of 220 cubic
ft.
of gas per hour. The farthest appliance
is the range, which is 50
ft.
(15.2 m) away from the meter. According to the chart above, the 50-
ft.
(15.2 m) column
shows that
Section
A to B must be 1" in order to supply 220 cubic
ft
per hour.
10' (3.1 m)
Length
1" Pipe size
e
l
p
m
a
x
e
g
n
i
z
i
s
s
a
G
(Natural Gas)
Pipe Size
Length:
ft.
(m)
Diameter:
in.
10'
(3.0)
20'
(6.1)
30'
(9.1)
40'
(12.2)
50'
(15.2)
60'
(18.3)
70'
(21.3)
80'
(24.4)
90'
(27.4)
100'
(30.5)
125'
(38.1)
150'
(45.7)
200'
(61.0)
1/2"
172
118
95
81
72
65
60
56
52
50
44
40
34
3/4"
360
247
199
170
151
137
126
117
110
104
92
83
71
1"
678
466
374
320
284
257
237
220
207
195
173
157
134
1
1/4"
1,309 957
768
657
583
528
486
452
424
400
355
322
275
1
1/2"
2,090 1,430 1,150 985
873
791
728
677
635
600
532
482
412
2"
4,020 2,760 2,220 1,900 1,680 1,520 1,400 1,300 1,220 1,160 1,020 928
794
Unit: Cubic feet per hour
Unit: kBTU per hour
The following tables are from NFPA 54
-Natural Gas Supply Piping-
Maximum delivery Capacity of Cubic Feet of Gas per Hour of IPS Pipe carrying Natural Gas with 0.60
Specific G
ravity
Based on Pressure Drop of 0.5" W.C.
Based on Energy Content of 1,000 BTU/Cubic
ft.:
The boiler requires 140 Cubic
ft./hr.
Pipe Size
Length:
ft.
(m)
Diameter
10'
(3.0)
20'
(6.1)
30'
(9.1)
40'
(12.2)
50'
(15.2)
60'
(18.3)
70'
(21.3)
80'
(24.4)
90'
(27.4)
100'
(30.5)
125'
(38.1)
150'
(45.7)
200'
(61.0)
1/2"
268
184
148
126
112
101
93
87
82
77
68
62
53
3/4"
567
393
315
267
237
217
196
185
173
162
146
132
112
1"
1,071
732
590
504
448
409
378
346
322
307
275
252
213
1
1/4"
2,205 1,496 1,212 1,039
913
834
771
724
677
630
567
511
440
1
1/2"
3,307 2,299 1,858 1,559 1,417 1,275 1,181 1,086 1,023
976
866
787
675
2"
6,221 4,331 3,465 2,992 2,646 2,394 2,205 2,047 1,921 1,811 1,606 1,496 1,260
-Propane (LP) Supply Piping-
Maximum Capacity of Propane (LP) Based on 11" W.C. supply pressure at a 0.5" W.C. pressure drop