FIXTURES

No 

f

ixtures can be mounted on the tub deck. Floor and wall-mounted fixtu

r

es are required.

Wall-Mounted

The position of the tub and the reach of the spout are critical. Pay special attention to the spout

reach when choosing your fixtu

r

es. Be careful to ensure the spout will extend out far enough to clear the tub deck

and the falling water will not hit too high up the side wall of the tub and splash.

Floor-Mounted

Some freestanding fixtu

r

es must be anchored to the tub drain for stabilization.

6


Remote Mounting Blower: 

Due to the limited space between the inner and outer shell on all of

  t

he Metro

 

C

ollection

 

f

reestanding tubs, the blower must be remote mounted. In addition to the air pipe there is one

 

electrical connection

 

between the tub and the blower. Th

e electrical co

nnection and the air pipe exit through the

 

bottom end of the bath.

 

It is always desirable to remote mount the air blower as close to the tub as possible to

 

minimize loss of heat.

 

Pipe

 

insulation may be used on the air line to minimize heat loss.

.

THERMAL AIR 

LOOP

Blower

Air hose 
(connect to tub)

1 ½” schedule 

40 PVC pipe 

(not supplied)

1 ½”

check valve 

(supplied)

 This is a sub floor drain. Access from below tub is recommended for installation. If there is no access from

 

below, the installation is more difficult. Clearance for the drain will be required and the floor near the overflow will

 

need to be completed after the drain is installed. 

Please s

ee picture below

.

Hydro Systems recommends using clear 100% silicone sealant

DO NOT use plumber’s putty.

INSTALLATION  INSTRUCTIONS

Thermal Air Loop:

 

A loop made of 1 ½” 

schedule 40 PVC

 

must be installed at the 

outlet of the blower

 

(PVC pipe and 90-

degree fittings not supplied) and must be at 
least 2” above

 

rim of tub with 1 ½” check 

valve (supplied) installed in horizontal 
position at the top

 

of the loop. If loop 

cannot be installed at blower location it can 
be installed at an alternate location in line 
prior to tub. If blower is installed at least 2” 
above rim of tub, attic or closet loop is not 
required. Please see illustration to the right.

Summary of Contents for Ston Series

Page 1: ...ubs without a pedestal page 6 User maintenance and cleaning instructions page 7 Limited warranty page 8 1 C O L L E C T I O N Please refer to www hydrosystem com for videos on how to install your bathtub and get specific dimensions on your model bathtub INSTALLER Please pass these important instructions along to the homeowner INSTALLATION INSTRUCTIONS FOR FREESTANDING MODELS TABLE OF CONTENTS ...

Page 2: ...educe the risk of electric shock connect this terminal to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to the circuit conductors supplying this equipment 1 DANGER RISK OF ELECTRICAL SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 This unit should be installed by a qualified service representative All electrica...

Page 3: ...ation Clean the drain hole area in preparation of setting the drain The area should be dry and free of any debris Measure and dry fit all connections Cut tubes as necessary Primer then glue drain elbow and female adapter Primer and glue elbow to tee and adapter Figure 3 Apply a thin ring of silicone around the underside of the strainer Position gasket between the drain ell and the bottom of the ba...

Page 4: ...rain hardware previously installed D980 CAP 2 7 8 5 16 1 1 2 OD Tubing 20 ga Cut to Fit Tub Dimensions Overflow O Ring 792A BJ UPC C WB 17 GA 24 D980 RING FIGURE 7 OVERFLOW INSTALL 13 Apply a thin bead of silicone around face of the overflow O ring Mount the D980 RING using the provided screws Figure 7 Adjust the ball joint to the contours of the tub and tighten the ring 14 Slide the escutcheon on...

Page 5: ...er that the drain lines up with the P trap in the floor DO NOT LET THE TUB REST ON THE DRAIN PLUMBING Check the tub for level It must be level end to end and side to side Caulk the gap between the skirt and the floor ELECTRICAL REQUIREMENTS WARNING When using electrical products basic precautions should always be followed including the fol owing DANGER RISK OF ELECTRICAL SHOCK Connect only to a ci...

Page 6: ...possible to minimize loss of heat Pipe insulation may be used on the air line to minimize heat loss THERMAL AIR LOOP Blower Air hose connect to tub 1 schedule 40 PVC pipe not supplied 1 check valve supplied This is a sub floor drain Access from below tub is recommended for installation If there is no access from below the installation is more difficult Clearance for the drain will be required and ...

Page 7: ...ve the drain kit from the tub Use emery cloth grinder or wire brush to remove the plated finish from the pipe where it will be soldered to the tee Provide opening in floor below drain of approximately 6 x 6 This will be completely covered by the tub Install tub in precise location desired Use only 100 clear silicone to adhere tub to floor Using the distance noted in step 4 drill hole in floor for ...

Page 8: ...WARRANTY OF MECHANTABILITY FITNESS NOR OTHER WARRANTY WHETHER EXPRESS IMPLIED OR STATUTORY IS MADE BY HYDRO SYSTEMS INC EXCEPT THAT IT WARRANTS THE GOODS TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP IN NORMAL USE AND SERVICE AS DESCRIBED ON THE FACE HEREOF WARRANTY OBLIGATIONS OF HYDRO SYSTEMS INC Should a defect in workmanship and or material in any item covered by this warranty become ev...

Reviews: