![Hydro systems EvoRinse Installation And Operation Manual Download Page 11](http://html.mh-extra.com/html/hydro-systems/evorinse/evorinse_installation-and-operation-manual_2191881011.webp)
11
3. Troubleshooting
Dead unit
• Confirm the main power connection voltage.
• Check main power source fuse.
WARNING
Electrical installation and maintenance should be completed by a
qualified electrician. All local and national electrical regulations are to
be observed.
4. Maintenance
Routine maintenance on the ‘EvoRinse’ includes:
• Keeping the spray nozzle free from scale and other deposit build up.
• Keeping the pump tube fresh.
• Keeping the unit clean.
• Clean the water filter mesh. Unscrew and rinse the mesh in clean
water.
Every Maintenance Visit
• Clean the unit cabinet with a damp cloth.
• Check the pump tube’s condition and replace, if needed.
• Clean the water filter mesh. Unscrew and rinse the mesh in clean
water.
Spray Nozzle Replacement
• Using a ½” socket, unscrew the nozzle, being careful not to exert
too much strain on the nozzle holder.
• Screw the new nozzle into the nozzle holder and tighten until hand
tight. Do not overtighten the nozzle as it could cause the nozzle
holder to break.