6.OO troubleshooting
6.O1 Troubleshooting Table
Problem
Cause
Solution
1. Dead unit - No LEDs illuminated
a. No incoming main electrical power
• Check wiring from dish machine.
• Check for power at dish machine connection.
b. Bad PC board
• If board has failed, replace the CP-500 unit.
2. No chemical dispensing.
a. No signal received
• Check signal wiring to dish machine.
• Check that dish machine is sending a signal.
b. Unit is not primed
• Prime the unit by using the Priming position of the
power switch, or by activating the appropriate signal
to run the pump.
c. Power switch is in the wrong position
• Confirm the power switch is in the
I
(ON) position
d. Pump tube is damaged or worn
• Replace pump tube as needed.
e. Foot filter is clogged, or incorrectly positioned
• Remove the foot filter and clean as needed.
• Check to insure the weight is installed correctly and
the filter is positioned at the bottom of the container.
f. Clogged delivery tube or bad connection
of tubing or fitting
• Check and tighten all connectors.
• Replace tubing and fittings as needed.
3. Excessive or inadequate chemical consumption
a. Incorrect pump wiring
• Check wiring from dish machine.
b. Clogged delivery tube or bad connection
of tubing or fitting
• Check and tighten all connectors.
• Replace tubing and fittings as needed.
c. Worn pump tube
• Replace pump tube as needed.
7.O1
Specifications
(
Specifications subject to change without notice.
)
Category
Specification
Size
5.0 in (128 mm) High x 3.6 in (91 mm) Wide x 4.1 in (104 mm) Depth
Weight
2.4 lb (1.1 kg)
Power Rating
90 to 260 VAC at 50/60 Hz up to 50 mA
Flow Rate
(at full speed)
Detergent Pumps: 100 ml/min (3.4 oz/min)
Rinse Pumps: 17 ml/min (0.57 oz/min)
Duty Cycle
20 hours on, 4 hours off
Regulatory Approvals
(CE)
Standard: 89/336/CEE
Regarding “Electromagnetic Compatibility” and the subsequent modifications 92/31/CEE,
93/68/CEE and 93/97/CEE
Standard: 72/23/CEE
Regarding “Low Voltages”, and the subsequent modification 93/68/CEE, 2002/95/CE,
2002/96/CE and 2003/108/CE “RoHs and WEEE Directive”
Wetted Parts: Material of Construction
Chemical Pickup “Foot Filter”
Polypropylene
Chemical Pickup Tubing
Santoprene
®
(Detergent and Rinse models)
Pump Squeeze Tube
Santoprene
®
(Silicone is available on request.)
Pump Discharge Tubing
PVC for Detergent models / Polyethylene for Rinse models
Injection Fitting(s)
Polypropylene
Environmental Specifications
Intrusion Protection (IP) Rating
IP Rating: 58
Temperature
10° to 49° C (50° to 120° F) maximum
Humidity
95% relative humidity, maximum
Indoor Installation
Approved for indoor use only. Must not be installed outdoors.