13
4.OO service parts
Category
Part No.
Description
Replacement squeeze tubes with compression fittings (packs of 10).
HYD10099124
10-Pack Santoprene®
HYD10099125
10-Pack Silicone
Installation Kits
Pickup / discharge tubing, foot filter, weight, injection fittings, mounting bracket and hardware
HYD10099142
CE Detergent Install Kit
HYD10099143
CE Rinse Install Kit
HYD10099144
UL Detergent Install Kit
HYD10099145
UL Rinse Install Kit
CP-500
Squeeze Tube
Install Kit
(Typical)
3.OO operation
3.O1 Description of Controls
Overview
The CP-500 makes use of 1 or 2 potentiometers for setting run times and/
or speed, a power/prime switch, and a multi-color LED for indicating the
dispenser status. The power/prime switch and LED status indications are
described below.
Power/Prime Switch Operation
Found on the bottom of pump body, the switch has 3 positions:
I
: The pump is active (ON). The pump will run normally. If no signal is
present, the LED will be off.
O
: The pump is in stand-by (OFF). The LED will be fixed red.
II
: The pump is in priming mode. The LED will be fixed orange.
The
II
position of the switch is “momentary”. In priming mode the pump
will run at full speed for 60 seconds.
If the
II
position of the switch is pressed again, before the 60 seconds
have elapsed, the pump will stop, and the switch will return to the stand-
by position.
CP-500 Power / Prime Switch
Switch Position
O
= Stand-by (OFF)
LED is fixed red
Switch Position
II
= 60 sec Prime
LED is fixed orange