![Hydro systems 113205 Operating Manual Download Page 12](http://html.mh-extra.com/html/hydro-systems/113205/113205_operating-manual_2191895012.webp)
English: 12
Routine Maintenance Instructions - 10%
Step 1.
Unscrew LOWER END
ASSEMBLY from body.
Step 2.
Remove LOWER END ASSEMBLY .
Step 4.
Remove the #73 DOSAGE PISTON
GUIDE and replace #44 DOSAGE
PISTON and #14 O-ring.
Step 3.
Remove #93 CAPSCREW from the
end of the shaft using a wrench
and nut driver.
Step 5.
Unscrew #72 ADAPTER and
remove.
Step 6
.
Remove and replace #17 O-RING
Step 7.
Re-install the new #44 DOSAGE
PISTON and #73 DOSAGE PISTON
GUIDE. Tighten snug using a nut
driver.
Step 8.
Screw LOWER END ASSEMBLY
onto body. Hand tighten only.
↓
↓
↓
Step 7a.
NOTE: #44 DOSAGE PISTON must
be installed
flared end up
.
↓
↓