English
English: 11
Routine Maintenance Instructions
0.3%, 2.5%, 5%
Step 1.
Unscrew LOWER END
CYLINDER ASSEMBLY from
body. Remove LOWER END
CYLINDER ASSEMBLY
Step 3.
Pry the #15 SEAL RETAINER from
the injector. Pry #17 O-RING from
the unit. NOTE: O-ring may still be
seated at the base of the unit.
Step 2.
Rotate #51 SHAFT 90º and pull
from body.
Step 4. For 2.5% & 5%
Replace #44 DOSAGE PISTON
flared-end up and #14 O-RING.
Step 6
.
Reinsert #15 SEAL RETAINER
and #17 O-RING onto # 51
SHAFT ASSEMBLY.
Step 7.
Reinsert #51 SHAFT ASSEMBLY into
body and rotate 90º to lock. Confirm
the shaft is locked in by gently
tugging on the shaft. Shaft should
remain inserted.
Step 8.
Screw LOWER END CYLINDER
ASSEMBLY onto body. Ensure
#16 GASKET
is seated on the top
of cylinder assembly.
Step 5a. For 0.3%.
Replace LOWER SHAFT ASSEMBLY
#51 into upper shaft.
↓
↓
Step 5. For 2.5% WSP
Pinch and pull #44 DOSAGE
GASKET over the retainer lip. Slide
off the #51 SHAFT ASSEMBLY.
↓