Normal
Operation
29
│
Page
TEMPERATURE
SETTINGS
‐
Without
remote
controller
‐
There
are
4
temperatures
that
you
can
select
from
by
changing
the
dipswitch
settings
on
the
computer
board
without
the
remote
controller.
See
the
table
below.
Temperatures
available
113
F
122
F
131
F
140
F
For
detailed
dipswitch
settings
for
each
temperature,
refer
to
the
next
page.
The
temperature
has
been
preset
at
the
factory
to
122°F
(50°C).
If
temperatures
other
than
the
ones
listed
above
are
required,
the
remote
controller
can
provide
several
more
temperature
options.
Refer
to
p.
9
for
a
list
of
available
temperatures
on
the
remote
controller.
This
water
heater
is
an
on
‐
demand,
tankless
water
heater
designed
to
efficiently
supply
endless
hot
water
without
reference
to
temperature
settings.
Dipswitches
‐
Dipswitch
settings
for
each
temperature
on
the
computer
board
‐
(45
OFF
ON
C)
113 F
1 2 3 4 5 6 7 8
OFF
ON
1 2 3 4 5 6 7 8
(50 C)
122 F
DEFAULT
(55
OFF
ON
C)
131 F
1 2 3 4 5 6 7 8
(60
OFF
ON
C)
140 F
1 2 3 4 5 6 7 8
Temperature
Settings
Turn
off
the
power
supply
to
the
water
heater
before
changing
the
dipswitch
settings.
Only
change
the
switches
with
the
dark
squares.
The
dark
squares
indicate
which
direction
the
dipswitch
should
be
set
to.
WARNING