Maintenance and service

                                                                             

 

Examination before trial run   

1. Check the water tank is filled with water, and open the water outlet tap till water flow out.   
2. Check the water pressure is normal (0.15Mpa~0.7Mpa).   
3. Check the air inlet or outlet is well connected; and the air outlet pipe heat insulation is completed.   
4.  Check  the  power  supply  voltage  is  normal, whether  according  with  the  nameplate  requirement. 

(Range ± 10%).   

5. Check whether the equipped parts are screwed /locked well.   
6.  Check  whether  the  wirings  are  according  with  the  Circuit  diagram,  and  the  earth-wire  is 

connected.   

7. Check whether the wind inlet and outlet has been cleaned up and no obstacle.   
8. Check whether the condensate drain pipe is connected well and no blockage.   
9. After power-ON, check the control panel display is normal.   

 

Trial running   

1.  After  the  machine  starts,  to  hear  and  determine  whether  there  is  abnormal  sound  or  collision 

during operation, if there is abnormal sound, stop the unit immediately and check for it until there 
is no abnormal sound to continue operation.   

2. For the first time power on, the compressor will have 3 minutes delay protection function.   
3.  Observe  whether  the  drainage  of  condensate  water  is  smooth,  prevent  the  chassis  stagnant  or 

spill water.   

4. For the first time discharge hot water or start the units after a long time closure, the water tap of 

outlet pipe may flow muddy water, this is a normal phenomenon, and continue to drain for a period 
of time can be cleared.   

5. After stop operation for a long time, there may have condensation water hereabout the air outlet or 

pipe (especial in humidity weather), this is a normal phenomenon, use a dry washcloth to clean it 
or by air dry.   

6. The advance setting parameters of the operation panel has been set at the factory, users no need 

to reset it, the maintenance person should be carefully set if needed.   

 

Maintenance and service   

1. After carry and move the unit by the first time installation, and connects the water pipes and filled 

the tank with water. The machine should be rest for 1-2 hours before start trial running.   

2. The water heater inlet filter needs to be cleaned once per 3 months. At the same time, per half 

year we suggest draining all the storage water and repeatedly wash for 2-3 times to remove the 
dirt and sediment.   

3. To keep the unit in good heating performance, suggest cleaning the Air inlet /outlet filter net per 

month, or using high pressure air tube to clean the Heat exchanger. Be careful not to damage the 
copper tube.   

4. Clean the Electric Heater per 6 months. (When clean the Electric Heater or Heat Exchanger must 

cut off power supply.)   

5. Change the Anode (Magnesium rod) per 6 months for better anticorrosion and antiscale.   

According to different water quality, change the Anode rod when it

’s expended.   

6. When clean the Tank, Electric Heater, Heat Exchanger or Anode rod must cut off power supply.   
7. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a 

similarly qualified person.   

8. Special statement: for what does not in accordance with the requirements of above maintenance 

and service work lead to the failure problem, does not apply to our warranty scope.   

Summary of Contents for Aqua-Man 260L

Page 1: ... your power bill with Hydro Hero ENERGY EFFICIENT SOLUTIONS EES the heat pump specialists f 0800 EES 123 p 09 973 5993 e info eesnz co nz ENERGY EFFICIENT SOLUTIONS EES the heat pump specialists POWERED BY ...

Page 2: ...kW Rated input output electric kW Max current amps Max input power kW Rated output water temp Power supply V COP at 20 EN255 3 COP at 15 EN255 3 COP at 7 EN255 3 Refrigerant Noise level dB A Air flow m3 h Tank construction Dimensions mm Pressure rated max MPa Gross weight KG Compressor specification Warranty heat pump Cylinder 260L 0 7kW 2 8kW 2kW 2kW 15 amps 3 3kW 55 70 220V 4 21 3 88 2 95 R134a ...

Page 3: ...Hydro Hero Heat Pump Water Heater INSTRUCTIONS ...

Page 4: ...Water Inlet Drainage Hole Screen Panel Evaporater Magnesium Anode Hole Electric Heater Cover Electric Heater Hole Decoration Bar Electric Board Compressor Tank Cover Decoration Panel Left Right Decoration Bar Condensate Drain Hole Circulation Water Hole Wiring Hole Power Line Temp Sensor Tube Hole Circulation Water Hole Hot Water Outlet ...

Page 5: ...Operation RI FRQWUROO panel ...

Page 6: ...过55 时 显示屏上 高温 提示亮 Set Temperature High Temperature Alarm Auxiliary Heater Status HTG Heating DEF Defrost WARM Keep warm Working Mode Time adjustment Time Timer On Timer Off Timer Period Water Temperature Temperature Gradient Note When the water temperature exceeds 55 the indicator light on display ...

Page 7: ...r F21 Compressor start delay 0 10 3 minute F28 Econ mode turn on or off electric heater 0 1 1 F29 Heat pumps working or not in heater mode 0 1 1 Defrost F31 Defrost start temp 20 20 2 C F32 Defrost finish temp 0 50 25 C F33 Defrost start time 1 999 30 minute F34 Max defrost time Off 1 99 5 minute Alarm F50 Low pressure alarm mode 0 2 2 F51 Auto resume times of low pressure alarm 0 10 3 time F52 Re...

Page 8: ...lve EEV F70 EEV opening query 0 480 F71 EEV control mode 0 2 0 F72 Manually set EEV opening 100 480 350 F73 Set EEV superheat degree 15 15 5 F74 Set EEV discharge temp 85 110 92 F79 Return gas temp System Setting F80 Password OFF 0001 9999 4321 OFF means no password Set 0000 to clear password F85 Display sterilization total time hour Testing F98 Force defrosting refrigeration Control panel display...

Page 9: ... temp is too high 2 Change the Electric heater A7 Exhaust temperature too high 1 Lack of refrigerant 2 Mix with air in system 3 Lack of lubricating oil 1 Supply refrigerant 2 Re vacuumizing and fill in refrigerant 3 Change the lubricating oil of compressor A8 Condensate drain hole blocked 1 condensate pipe blocked 2 Machine drain hole blocked 1 Check condensate pipe is blocked or not 2 Check machi...

Page 10: ...ation for a long time there may have condensation water hereabout the air outlet or pipe especial in humidity weather this is a normal phenomenon use a dry washcloth to clean it or by air dry 6 The advance setting parameters of the operation panel has been set at the factory users no need to reset it the maintenance person should be carefully set if needed Maintenance and service 1 After carry and...

Page 11: ...p vertically 15 20mm then pull it out horizontally to separate hook A 2 from hook A 3 until exposed butt splice connector 2 Disconnect control panel with butt splice connector 3 Remove all screws 5 from the bottom of the top cover 4 Release the power line from the top cover of fixed terminal to prevent the power line stuck when move up the top cover 5 Finally remove the block objects e g air ducts...

Page 12: ... POWER SUPPLY YELLOW GREEN Transformer WATER TEMP SENSOR OPERATION PANEL ELECTRIC HEATER YELLOW GREEN 4 WAY VALVE FAN MOTOR YELLOW GREEN ELECTRIC HEATER PROTECTOR PRESURE PROTECTOR Electronic expansion valve AMBIENT TEMP SENSOR COIL TEMP SENSOR EXHAUST TEMP SENSOR RETURN GAS TEMP SENSOR N BXS HI LOW COMPRESSOR 5 RED 220V ...